Usefulness of transesophageal echocardiography in percutaneous transcatheter repairs of paravalvular mitral regurgitation

M Cortés, E García, MA García-Fernandez… - The American journal of …, 2008 - Elsevier
transesophageal echocardiography (TEE) as a guide in the percutaneous transcatheter
occlusion of paravalvular … with mitral paravalvular leaks with significant regurgitation considered …

[PDF][PDF] The role of 3D transesophageal echocardiography during percutaneous closure of paravalvular mitral regurgitation

C Hamilton-Craig, T Boga, D Platts… - JACC: Cardiovascular …, 2009 - academia.edu
mitral valve replacement may lead to heart failure and hemolysis. There are data to suggest
that closure of paravalvular mitral regurgitant … closure of paravalvular mitral regurgitation is …

Long-term follow-up of mitral paraprosthetic regurgitation by transesophageal echocardiography

HD Movsowitz, SI Shah, A Ioli, MN Kotler… - … of Echocardiography, 1994 - Elsevier
Paravalvular regurgitation (PVR) is an uncommon complication of mitral valve replacement
(MVR… Quantitation of mitral regurgitation by transesophageal echocardiography with Doppler …

Paravalvular regurgitation after transcatheter aortic valve replacement: comparing transthoracic versus transesophageal echocardiographic guidance

SS Hayek, FE Corrigan III, JF Condado, S Lin… - … of Echocardiography, 2017 - Elsevier
… operating room with transesophageal echocardiography (TEE) guidance (TEE-TAVR;
mean Society of Thoracic Surgeons score, 11%). All patients received an Edwards valve (SAPIEN …

Accurate localization of mitral regurgitant defects using multiplane transesophageal echocardiography

GP Foster, EM Isselbacher, GA Rose… - The Annals of thoracic …, 1998 - Elsevier
… Twenty-three of these sections contained paravalvular leaks by transesophageal
echocardiography (mean number of leaks per prosthesis, 2.1; range, 1 through 6). There was …

[PDF][PDF] The value of real-time three-dimensional transesophageal echocardiography in the assessment of paravalvular leak origin following prosthetic mitral valve …

M Yıldız, NE Duran, T Gökdeniz, H Kaya… - Türk Kardiyol Dern …, 2009 - jag.journalagent.com
… the origin of paravalvular leak (PVL) that occurs after prosthetic mitral valve replacement (MVR…
-time three-dimensional transesophageal echocardiography (RT-3D TEE) in detecting the …

Live/real time three‐dimensional transesophageal echocardiographic evaluation of mitral and aortic valve prosthetic paravalvular regurgitation

P Singh, J Manda, MC Hsiung, A Mehta… - …, 2009 - Wiley Online Library
… study was to compare 3D TEE with 2D TEE in the evaluation of prosthetic paravalvular
dimensional transesophageal echocardiogram shows medial paravalvular (P) mitral regurgitation

Value and limitations of transesophageal echocardiography in assessment of mitral valve prostheses.

BK Khandheria, JB Seward, JK Oh, WK Freeman… - Circulation, 1991 - Am Heart Assoc
… In addition, there were two patients with moderate or severe perivalvular mitral regurgitation
but no two-dimensional TEE evidence of dehiscence who had posteromedially located de…

Utility of real-time three-dimensional transesophageal echocardiography in evaluating the success of percutaneous transcatheter closure of mitral paravalvular leaks

MA García-Fernández, M Cortés… - … of Echocardiography, 2010 - Elsevier
… (2D) transesophageal echocardiography (2DTEE). The surgical closure of paravalvular leaks
is … mitral valve leak closure, in which total or a highly significant reduction in the severity of …

Real-time 3-dimensional transesophageal echocardiography in the evaluation of post-operative mitral annuloplasty ring and prosthetic valve dehiscence

I Kronzon, L Sugeng, G Perk, D Hirsh, L Weinert… - Journal of the American …, 2009 - jacc.org
… We used RT 3D TEE to evaluate mitral regurgitation after mitral valve repair … Mitral valve
replacement and repair may be complicated by post-operative paravalvular mitral regurgitation (…