A fast-time-response extreme ultraviolet spectrometer for measurement of impurity line emissions in the Experimental Advanced Superconducting Tokamak

L Zhang, S Morita, Z Xu, Z Wu, P Zhang… - Review of Scientific …, 2015 - pubs.aip.org
… A flat-field extreme ultraviolet (EUV) spectrometer working in the 20-500 Å wavelength range
with fast time response has been newly developed to measure line emissions from highly …

… extreme ultraviolet spectrometer working at 10–130 Å for tungsten spectra observation with high spectral resolution and fast-time response in Experimental Advanced …

Z Xu, L Zhang, Y Cheng, S Morita, L Li, W Zhang… - … , Spectrometers …, 2021 - Elsevier
… The modern EUV spectrometer is … -time response (5 ms/frame) EUV spectrometer working
at 20–500 Å called ‘EUV_Long’ developed in EAST [28]. A space-resolved EUV spectrometer

Development of a time-resolved attenuated total reflectance spectrometer in far-ultraviolet region

Y Morisawa, N Higashi, K Takaba… - Review of Scientific …, 2012 - pubs.aip.org
… A far-ultraviolet transient absorption spectrometer based on time-resolved attenuated total …
The time resolution, which was determined by the time response of a continuous light detector…

Ultraviolet spectrometer experiment for the Voyager mission

AL Broadfoot, BR Sandel, DE Shemansky… - Space Science …, 1977 - Springer
The Voyager Ultraviolet Spectrometer (UVS) is an objective grating spectrometer covering
the wavelength range of 500–1700 Å with 10 Å resolution. Its primary goal is the …

A Fourier transform spectrometer for the vacuum ultraviolet: design and performance

AP Thorne, CJ Harris, I Wynne-Jones… - Journal of Physics E …, 1987 - iopscience.iop.org
… A Fourier transform spectrometer designed to operate at high resolution at wavelengths … ),
and (iv) a significant luminosity gain over grating spectrometers operating in the same region. …

ULTRA: A unique instrument for time-resolved spectroscopy

GM Greetham, P Burgos, Q Cao, IP Clark… - Applied …, 2010 - opg.optica.org
… -sensitivity time-resolved infrared and Raman spectrometer … provide wavelength tuning
from the ultraviolet (UV) to the mid-… time response and range required. With the pump (fs)Àpump …

Simple ultraviolet calibration source with reference spectra and its use with the Galileo orbiter ultraviolet spectrometer

JM Ajello, DE Shemansky, B Franklin, J Watkins… - Applied …, 1988 - opg.optica.org
… concerned with temporal variation in instrument response. … A calibration of a UV spectrometer
with the electron impact … than acquiring guest investigator time at the National Bureau of …

Galileo ultraviolet spectrometer experiment

CW Hord, WE McClintock, AIF Stewart, CA Barth… - The Galileo …, 1992 - Springer
… version of the Voyager Ultraviolet Spectrometer, covering the … by the Voyager Ultraviolet
Spectrometer form a solid point of … Figure 7 is a plot of the normalized off-axis response ofthe …

In situ calibration of an extreme ultraviolet spectrometer for attosecond transient absorption experiments

X Wang, M Chini, Y Cheng, Y Wu, Z Chang - Applied optics, 2013 - opg.optica.org
spectrometer. Therefore, the linewidth of the measured argon absorption spectrum should
be larger than the spectrometer … convoluted by the spectrometer response function [20,21]: …

A Fourier transform spectrometer without a beam splitter for the vacuum ultraviolet range: From the optical design to the first UV spectrum

N De Oliveira, D Joyeux, D Phalippou… - Review of Scientific …, 2009 - pubs.aip.org
… The determination of the impulse response distortion and of the noise on the vacuum ultraviolet
… These UV measurements are very close to those found in the literature, showing nominal …