Stylized versus voxel phantoms: a juxtaposition of organ depth distributions

KT Griffin, TA Cuthbert, SA Dewji… - Physics in Medicine & …, 2020 - iopscience.iop.org
… in organ positioning between a stylized and voxel phantom series. Specific to the RORNL
stylized and UF/NCI voxel phantom series, some interesting trends in organphantom organ

The GSF family of voxel phantoms

N Petoussi-Henss, M Zankl, U Fill… - Physics in Medicine & …, 2001 - iopscience.iop.org
… Table 2 shows the masses of some selected organs of the GSF voxel phantoms. A voxel
phantom based on an Asian individual was developed for the first time: Otoko was Japanese …

The reference phantoms: voxel vs polygon

CH Kim, YS Yeom, TT Nguyen, ZJ Wang… - Annals of the …, 2016 - journals.sagepub.com
… models of the Publication 110 reference phantoms were converted directly to the PM format.
… simple organs and the other for more complex organs. For very simple organs, the voxel

iPhantom: A Framework for Automated Creation of Individualized Computational Phantoms and Its Application to CT Organ Dosimetry

W Fu, S Sharma, E Abadi, AS Iliopoulos… - IEEE journal of …, 2021 - ieeexplore.ieee.org
… and target voxel phantoms by assigning organ intensities (HU … organ voxels of the XCAT
patient CT images. For label-based phantom input, the template and target voxel phantoms

The application of voxel phantoms to the internal dosimetry of radionuclides

M Zankl, N Petoussi-Henss, U Fill… - Radiation protection …, 2003 - academic.oup.com
organ and tissue masses of the voxel models of this study are presented in Table 2. For
comparison, organ … of the improved voxel model organ topology on SAFs and organ doses, this …

Development of a Japanese adult female voxel phantom

K Sato, H Noguchi, Y Emoto, S Koga… - Journal of nuclear …, 2009 - Taylor & Francis
organ doses or specific absorbed fractions (SAFs). Thus, we developed a Japanese adult
male voxel phantom … to improve the evaluation accuracy of organ doses or SAFs of Japanese …

[PDF][PDF] Two dedicated software, voxel-based, anthropomorphic (torso and head) phantoms

IG Zubal, CR Harrell, EO Smith, AL Smith… - … on Voxel Phantom …, 1995 - Citeseer
phantom has been updated to include female organs [2]. There are … of the voxel based
phantoms, we present two figures in which slices out of the torso+head and head phantom are …

Japanese adult male voxel phantom constructed on the basis of CT images

K Sato, H Noguchi, Y Emoto, S Koga… - Radiation Protection …, 2007 - academic.oup.com
… called voxel (volume pixel). Thus, the phantom consisting of voxels is called a voxel phantom.
The organ shapes of a voxel phantom can be modelled with high accuracy using a small …

Comparison of two types of adult phantoms in terms of organ doses from diagnostic CT procedures

H Liu, J Gu, PF Caracappa, XG Xu - Physics in Medicine & …, 2010 - iopscience.iop.org
… of percent in comparisons between a number of voxel phantoms developed at their
institution. Chao et al (2001) reported that the effective doses from the MIRD-type stylized …

Voxel anthropomorphic models as a tool for internal dosimetry

N Petoussi-Henss, M Zankl - Radiation protection dosimetry, 1998 - academic.oup.com
… to organ topology than the mathematical phantoms commonly used up to now. Selected
realism of the voxel models with respect to organ shape and location introduces, for some …