Three-dimensional relationship between high-order root-mean-square wavefront error, pupil diameter, and aging

RA Applegate, WJ Donnelly Iii, JD Marsack, DE Koenig… - JOSA A, 2007 - opg.optica.org
wavefront error (WFE) for individual aberrations and cumulative high-order (HO) RMS WFE
for the normal human eye as a function of age by decade and pupil diameterpupil diameters. …

[HTML][HTML] Change in visual acuity is highly correlated with change in six image quality metrics independent of wavefront error and/or pupil diameter

A Ravikumar, EJ Sarver, RA Applegate - Journal of vision, 2012 - iovs.arvojournals.org
… Abstract It is well known that the wavefront error (WFE) of the eye varies from individual to
individual with pupil diameter (PD) and age. Numerous studies have been proposed …

Effect of pupil size on wavefront refraction during orthokeratology

M Faria-Ribeiro, R Navarro… - Optometry and Vision …, 2016 - journals.lww.com
wavefront error maps of each patient, at nine different visual field angles and two pupil
diameters… Each wavefront matrix was used to compute the point-spread function, and the optical …

Noise in wavefront error measurement from pupil center location uncertainty

RA Applegate, JD Marsack… - Journal of Refractive …, 2010 - journals.healio.com
… re-sampling the WFE with respect to the new pupil center, assuming the shift of the pupil is
known and the WFE is known over a larger pupil diameter than the pupil diameter of interest. …

Wavefront technology: past, present and future

WN Charman - Contact Lens and Anterior Eye, 2005 - Elsevier
wavefront aberration of the eye is such that the rms wavefront error will tend to increase with
the pupil diameter… to an rms wavefront error of about 0.3 μm for a pupil diameter of 6 mm, …

Variability of wavefront aberration measurements in small pupil sizes using a clinical Shack-Hartmann aberrometer

HS Ginis, S Plainis, A Pallikaris - BMC ophthalmology, 2004 - Springer
… lower when calculated by the scaling method for a pupil diameter of 3 mm as compared to
the one … However, the use of a single measurement of the wavefront error in the planning of a …

Clinical applications of wavefront refraction

AS Bruce, LJ Catania - Optometry and Vision Science, 2014 - journals.lww.com
wavefront aberrometer applies a form of high-resolution autorefraction across the entire area
of the patient’s pupil, giving the wavefront error (… pupil diameter, because the pupil diameter

Influence of pupil and optical zone diameter on higher-order aberrations after wavefront-guided myopic LASIK

J Bühren, C Kühne, T Kohnen - Journal of Cataract & Refractive Surgery, 2005 - Elsevier
Wavefront errors were computed for pupil diameters (PDs) of 3.0, 3.5, 4.0, 5.0, 6.0, and 7.0
mm for the individual OZ diameter … of wavefront errors on the aperture diameter is well known, …

Measurement of the axial wavefront aberration of the human eye

G Walsh, WN Charman - Ophthalmic and Physiological Optics, 1985 - Wiley Online Library
… of the wavefront aberration; again the “ideal” wavefront would be flat. It is also evident that, …
when the pupil diameter reaches -3 mm. Root mean square (RMS) wavefront errors were also …

Accuracy and precision of objective refraction from wavefront aberrations

LN Thibos, X Hong, A Bradley… - Journal of vision, 2004 - jov.arvojournals.org
… ) a curve is generated relating RMS wavefront error to pupil radius. Each of these curves …
tessellating the entire pupil with small sub-apertures (about 1% of pupil diameter) and then …