Blood flow analysis of the aortic arch using computational fluid dynamics

S Numata, K Itatani, K Kanda, K Doi… - European Journal of …, 2016 - academic.oup.com
OBJECTIVES To obtain predictive information regarding aortic disease, we evaluated how
blood flow inside the aortic arch was influenced by thoracic aortic aneurysms. In addition, to …

Computational fluid dynamics modeling and analysis of the effect of 3-D distortion of the human aortic arch

D Mori, T Yamaguchi - Computer Methods in Biomechanics & …, 2002 - Taylor & Francis
An idealized CFD model and a realistic one were used to investigate the effect of the 3-D
distortion of the aortic arch on the blood flow and its pathophysiological significance with …

A computational fluid dynamics study on geometrical influence of the aorta on haemodynamics

KM Tse, R Chang, HP Lee, SP Lim… - European Journal of …, 2013 - academic.oup.com
OBJECTIVES Cardiovascular diseases, such as atherosclerosis and aneurysm, are closely
associated with haemodynamic factors that are governed by luminal geometry. The present …

Three-dimensional numerical simulation of blood flow in the aortic arch during cardiopulmonary bypass

Y Tokuda, MH Song, Y Ueda, A Usui… - European Journal of …, 2008 - academic.oup.com
Objective: To better understand the mechanism of stroke during cardiopulmonary bypass, it
is necessary to obtain information on the location of turbulence, wall pressure, and flow …

Three dimensional numerical analysis of hemodynamic of stenosed artery considering realistic outlet boundary conditions

A Bit, A Alblawi, H Chattopadhyay, QA Quais… - Computer methods and …, 2020 - Elsevier
Background and objective Mortality rate increases globally among which one third is due to
diseased blood vessels. Due to late diagnoses of the disease in vessels (severe stenoses) …

Unsteady and three-dimensional simulation of blood flow in the human aortic arch

N Shahcheraghi, HA Dwyer… - J. Biomech …, 2002 - asmedigitalcollection.asme.org
A three-dimensional and pulsatile blood flow in a human aortic arch and its three major
branches has been studied numerically for a peak Reynolds number of 2500 and a …

Effect of cannula length on aortic arch flow: protection of the atheromatous aortic arch

EA Grossi, MS Kanchuger, DS Schwartz… - The Annals of thoracic …, 1995 - Elsevier
Atheromatous disease in the transverse aortic arch is associated with an increased
incidence of perioperative stroke. In addition, tissue erosion in the aortic arch is caused by …

Aortic hemodynamics after thoracic endovascular aortic repair, with particular attention to the bird-beak configuration

GHW van Bogerijen, F Auricchio… - Journal of …, 2014 - journals.sagepub.com
Purpose: To quantitatively evaluate the impact of thoracic endovascular aortic repair
(TEVAR) on aortic hemodynamics, focusing on the implications of a bird-beak configuration …

Analysis of flow patterns in a patient-specific aortic dissection model

Z Cheng, FPP Tan, CV Riga, CD Bicknell… - 2010 - asmedigitalcollection.asme.org
Aortic dissection is the most common acute catastrophic event affecting the thoracic aorta.
The majority of patients presenting with an uncomplicated type B dissection are treated …

Computational hemodynamics in the human aorta: a computational fluid dynamics study of three cases with patient-specific geometries and inflow rates

C Karmonik, JX Bismuth, MG Davies… - … and Health Care, 2008 - content.iospress.com
Objective: To demonstrate the potential role of computational fluid dynamics (CFD) in
therapeutic decision making for treatment of vascular pathologies of the human aorta …