Effect of the embolization material in the dose calculation for stereotactic radiosurgery of arteriovenous malformations
OOG de la Cruz, JM Lárraga-Gutiérrez… - Medical …, 2013 - Elsevier
… Under these conditions, if the dose calculation does not have the accuracy required to … effect
of the embolization material on the probability of obliteration by comparing calculated doses …
of the embolization material on the probability of obliteration by comparing calculated doses …
[HTML][HTML] Effect of different embolization materials on proton beam stereotactic radiosurgery Arteriovenous Malformation dose distributions using the Monte Carlo …
… As a result of the calculations; We suggest that the embolization material should be chosen
whichever is more important from Bragg peak position/amplitude, recoils or lateral scattering …
whichever is more important from Bragg peak position/amplitude, recoils or lateral scattering …
[HTML][HTML] Dosimetric effects of embolization material artefacts in arteriovenous malformations stereotactic radiosurgery on treatment planning calculation
A Elawadi, M Alshanqity, H AlHussain… - … Imaging in Radiation …, 2022 - Elsevier
… that the pencil beam (PB) dose calculation algorithm overestimates the calculated dose. …
dosimetric effects of the embolic materials on the AVM treatment planning dose calculations in …
dosimetric effects of the embolic materials on the AVM treatment planning dose calculations in …
Stereotactic radiosurgery alone or combined with embolization for brain arteriovenous malformations: a systematic review and meta-analysis
… overall impact of embolic material confounding radiosurgical … of effect between the different
types of embolic materials on … AVM following embolization with Onyx: possible dosage error …
types of embolic materials on … AVM following embolization with Onyx: possible dosage error …
Stereotactic radiosurgery for arteriovenous malformations after Onyx embolization: a case-control study
… The propensity score was calculated in a … embolized AVMs may be the shield effect caused
by high atomic number elements in the embolic material and their attenuation of the dose of …
by high atomic number elements in the embolic material and their attenuation of the dose of …
… and Safety of Combined Endovascular Embolization and Stereotactic Radiosurgery for Patients with Intracranial Arteriovenous Malformations: A Systematic Review …
Z Jiang, X Zhang, X Wan, M Wei, Y Liu… - BioMed Research …, 2021 - Wiley Online Library
… effects of prior embolization in patients with IAVMs could be affected by nidus volume,
margin dose… Subsequently, the pooled effect estimates were calculated using the random-effects …
margin dose… Subsequently, the pooled effect estimates were calculated using the random-effects …
Combined effects of embolization and hypofractionated conformal stereotactic radiotherapy in arteriovenous malformations of the brain
P Lindvall, G Wikholm, P Bergström… - Interventional …, 2005 - journals.sagepub.com
… after embolization calculated from measurements done on X-ray film according to the
method described14 and the volumes of the AVMs determined by our three-dimensional dose …
method described14 and the volumes of the AVMs determined by our three-dimensional dose …
[HTML][HTML] Embolization and radiosurgery for arteriovenous malformations
AR Plasencia, A Santillan - Surgical neurology international, 2012 - ncbi.nlm.nih.gov
… The treatment of arteriovenous malformations (AVMs) … , endovascular embolization, and
stereotactic radiosurgery (SRS). … the potential impact of embolization material on radiation dose …
stereotactic radiosurgery (SRS). … the potential impact of embolization material on radiation dose …
Stereotactic radiosurgery for arteriovenous malformations: the effect of treatment period on patient outcomes
BE Pollock, MJ Link, SL Stafford, YI Garces… - Neurosurgery, 2016 - journals.lww.com
… , dose planning was based on a combination of stereotactic … our early practice underwent
embolization to reduce the nidus … Conformality indices have not been routinely calculated in …
embolization to reduce the nidus … Conformality indices have not been routinely calculated in …
Combined endovascular embolization and stereotactic radiosurgery in the treatment of large arteriovenous malformations
SL Blackburn, WW Ashley, KM Rich, JR Simpson… - Journal of …, 2011 - thejns.org
… an effort to reduce radiation side effects and ultimately promote … before embolization was
calcua lated by the following equation… A margin dose of 16–20 Gy was used in all but 1 case (1 …
calcua lated by the following equation… A margin dose of 16–20 Gy was used in all but 1 case (1 …