… for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies  …

MS Wathen, PJ DeGroot, MO Sweeney, AJ Stark… - Circulation, 2004 - Am Heart Assoc
… in implantable cardioverter-defibrillator (ICD) patients. Fast VT (FVT) >200 bpm is often treated
by … Furthermore, the fast charge time of the newly implanted ICDs in this study may have …

Safety and efficacy of programming a high number of antitachycardia pacing attempts for fast ventricular tachycardia: a prospective study

RP Martins, H Blangy, L Muresan, L Freysz… - Europace, 2012 - academic.oup.com
… about the optimal number of antitachycardia pacing (ATP) … All patients receiving an
implantable cardioverter/defibrillator (… to deliver ATP before or during charging in order to prevent …

… reduction with multiple bursts of antitachycardia pacing therapies to treat fast ventricular tachyarrhythmias in patients with implantable cardioverter defibrillators: a …

I Anguera, P Dallaglio… - Journal of …, 2015 - Wiley Online Library
… burst ATP therapy for terminating fast ventricular tachycardias (… of life require optimization of
the ventricular arrhythmia … to deliver ATP before or during charging in order to prevent shock …

ANTITACHYCARDIA PACING: OPTIMAL PROGRAMMING AND PREDICTION OF EFFICACY FOR THE TREATMENT OF VENTRICULAR ARRHYTHMIAS. STATE OF …

L Avolio, P Zappulla, N Valenti, ML Presti… - Authorea …, 2023 - techrxiv.org
… on optimal implantable cardioverterdefibrillator programming and … the value of a single burst
during charge (DC) programming, … of antitachycardia pacing in fast ventricular arrhythmias in …

Additional antitachycardia pacing programming strategies further reduce unnecessary implantable cardioverter-defibrillator shocks

B Joung, DR Lexcen, CK Ching, MT Silver, JP Piccini… - Heart Rhythm, 2020 - Elsevier
… used, and 1 ATP sequence during charging in the VF zone. The … the initial therapy at
terminating fast ventricular arrhythmias (75… pacing pulses, must also be considered when

Optimal implantable cardioverter defibrillator programming

BK Shah - Cardiology in Review, 2017 - journals.lww.com
… delivering ATP during capacitor charge significantly reduced the rate of … antitachycardia
pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable

Management of hemodynamically stable wide QRS complex tachycardia in patients with implantable cardioverter defibrillators

FD Regoli, M Cattaneo, F Kola, A Thartori… - Frontiers in …, 2023 - frontiersin.org
… minority also have an implantable cardioverter defibrillator (ICD). … treatment by proposing a
structured approach for the optimal … tested antitachycardia pacing in implantable cardioverter …

Failure to treat life-threatening ventricular tachyarrhythmias in contemporary implantable cardioverter–defibrillators: Implications for strategic programming

AM Thøgersen, JM Larsen, JB Johansen… - … : Arrhythmia and …, 2017 - Am Heart Assoc
… restrict therapy to regular rhythms in ventricular tachycardia … prevention for implantable
cardioverterdefibrillator (ICD), 2 … initiating VT because antitachycardia pacing slowed the VT to …

Failed anti-tachycardia pacing can be used to differentiate atrial arrhythmias from ventricular tachycardia in implantable cardioverter-defibrillators

KA Michael, A Enriquez, A Baranchuk, C Haley… - EP …, 2015 - academic.oup.com
… ) were used to determine the optimal cut-off values that would … All devices had a single burst
of ATP before/during charge … burst pacing in implantable cardioverter-defibrillator patients-…

Progressive implantable cardioverter-defibrillator therapies for ventricular tachycardia: The efficacy and safety of multiple bursts, ramps, and low-energy shocks

M Strik, FD Ramirez, N Welte, T Bonnin, S Abu-Alrub… - Heart Rhythm, 2020 - Elsevier
… on optimal implantable cardioverter-defibrillator programming … antitachycardia pacing (ATP)
for the treatment of ventricular … often treated with a burst of ATP before or during charging of …