[引用][C] Optimal Programming of Antitachycardia Pacing Functions

O Costantini, MD Carlson - Cardiac Electrophysiology Review, 1998 - Springer
… that capacitors be charged, antitachycardia pacing can be delivered … implantable cardioverter
defibrillator misclassifies a supraventricular tachyarrhythmia as ventricular tachycardia

[HTML][HTML] Optimal programming management of ventricular tachycardia storm in ICD patients

Z Qian, J Guo, Z Zhang, Y Wang, X Hou… - Journal of Biomedical …, 2015 - ncbi.nlm.nih.gov
cardioverter defibrillator (ICD) therapy within 24 hours. … of VT leading to ICD therapies [antitachycardia
pacing (ATP) or … during charging, significantly reduces the rate of appropriate …

The benefit of a second burst antitachycardia sequence for fast ventricular tachycardia in patients with implantable cardioverter defibrillators

I Anguera, P Dallaglio, X Sabate… - Pacing and Clinical …, 2014 - Wiley Online Library
… (ICDs), an empirical burst of antitachycardia pacing (ATP) is … of life require optimization of
the ventricular arrhythmia detection … before energy charge and the second one during charge) …

Management of implantable cardioverter defibrillator recipients: care beyond guidelines

F Philippon, LD Sterns, PB Nery, R Parkash… - Canadian Journal of …, 2017 - Elsevier
… received an ICD for ventricular arrhythmias (secondary prevention ICD … Optimizing the
arrhythmia rate when device therapy is triggered is … Programming antitachycardia pacing therapies

… to compare ramp versus burst antitachycardia pacing therapies to treat fast ventricular tachyarrhythmias in patients with implantable cardioverter defibrillators: the …

MM Gulizia, L Piraino, M Scherillo… - … : Arrhythmia and …, 2009 - Am Heart Assoc
… are clinically rapid monomorphic ventricular tachycardias (VT… patient’s quality of life require
optimization of the VT/VF detection … trial of the implantable cardioverter defibrillator against …

2019 HRS/EHRA/APHRS/LAHRS focused update to 2015 expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing

MK Stiles, L Fauchier, CA Morillo, BL Wilkoff - EP Europace, 2019 - academic.oup.com
… /implantable cardioverter-defibrillator (ICD) therapies where … Use of ATP Before/During
Charging in the VF zone achieves … 30ms) in the Fast VT zone will not prevent therapy but rather …

[HTML][HTML] Nonsustained ventricular tachycardia at the time of implantation predicts appropriate therapies on rapid ventricular arrhythmia in primary prevention patients …

N Clementy, A Bisson, F Challal, C Andre… - JACC: Clinical …, 2017 - jacc.org
… the benefits of implantable cardioverter-defibrillator (ICD) in … reduced LVEF despite optimal
medical therapy, who underwent … and antitachycardia pacing (ATP) before or during charging, …

Combination of antitachycardia pacemaker and automatic implantable cardioverter/defibrillator for ventricular tachycardia

M Manz, U Gerckens, HD Funke… - Pacing and Clinical …, 1986 - Wiley Online Library
… For antitachycardia pacing, a burst of rapid ventricular pacing ivas delivered af about 80% …
hospitalized again to optimize antiarrhythmic treatment. He was discharged on a comhination …

Impact of accelerated ventricular tachyarrhythmias on mortality in patients with implantable cardioverter-defibrillator therapy

C Schukro, L Leitner, J Siebermair, T Pezawas… - International journal of …, 2013 - Elsevier
… with implantable cardioverter-defibrillator (ICD)… Anti-tachycardia pacing and shock therapy
were defined as ICD interventions. Acceleration of VT and induction of ventricular arrhythmias

Rapid-rate nonsustained ventricular tachycardia found on implantable cardioverter-defibrillator interrogation: relationship to outcomes in the SCD-HeFT (Sudden …

J Chen, G Johnson, AS Hellkamp, J Anderson… - Journal of the American …, 2013 - jacc.org
… left ventricular ejection fraction ≤35%, and were on optimal HF … , a single premature ventricular
contraction after charge end … antitachycardia pacing versus shocks for spontaneous rapid