[HTML][HTML] Optimal Timing of Cardioverter-Defibrillator Implantation in Patients with Left Ventricular Dysfunction after Acute Myocardial Infarction
AM Ursaru, II Costache, AO Petris… - Reviews in …, 2022 - imrpress.com
… of life-threatening ventricular arrhythmias, as implantable cardiac … VT was primarily treated
with anti-tachycardia pacing (ATP) … primarily treated with ICD shock with ATP during charging. …
with anti-tachycardia pacing (ATP) … primarily treated with ICD shock with ATP during charging. …
… Cardiovascular Society/Canadian Heart Rhythm Society position statement on the management of ventricular tachycardia and fibrillation in patients with structural …
MW Deyell, A AbdelWahab, P Angaran… - Canadian Journal of …, 2020 - Elsevier
… est axé sur la prise en charge de la tachycardie ventriculaire (… an indication for an implantable
cardioverter-defibrillator (ICD)… as optimizing antitachycardia pacing [ATP]) or ICD therapy …
cardioverter-defibrillator (ICD)… as optimizing antitachycardia pacing [ATP]) or ICD therapy …
Minimizing inappropriate or “unnecessary” implantable cardioverter-defibrillator shocks: appropriate programming
JN Koneru, CD Swerdlow, MA Wood… - … : Arrhythmia and …, 2011 - Am Heart Assoc
… is less than optimal for AF with rapid ventricular response. Fourth, … antitachycardia pacing;
FVT, fast ventricular tachycardia. … would provide similar clinical benefit as ATP during charging. …
FVT, fast ventricular tachycardia. … would provide similar clinical benefit as ATP during charging. …
[HTML][HTML] Evolution of extravascular implantable cardioverter-defibrillator therapy for ventricular arrhythmias
H Römers, V van Dijk, L Boersma - Heart Rhythm O2, 2023 - Elsevier
… pacing indication that are in need for antitachycardia pacing … of the QRS to reduce charge
decision by ruling out T-wave … to the lead was the optimal position for effective unidirectional …
decision by ruling out T-wave … to the lead was the optimal position for effective unidirectional …
Who Should Receive the Subcutaneous Implanted Defibrillator? Timing Is Not Right to Replace the Transvenous Implantable Cardioverter Defibrillator
MR Acha, D Milan - Circulation: Arrhythmia and Electrophysiology, 2013 - Am Heart Assoc
… TV-ICDs allow ATP delivery during charging, enabling an initial round of … antitachycardia
pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable …
pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable …
Shock reduction using antitachycardia pacing for spontaneous rapid ventricular tachycardia in patients with coronary artery disease
MS Wathen, MO Sweeney, PJ DeGroot, AJ Stark… - Circulation, 2001 - Am Heart Assoc
… in ICD patients by optimizing ATP therapy. Furthermore, … therapy during capacitor charging
may be 1 method to prevent episode duration from increasing. Shocks can be aborted when …
may be 1 method to prevent episode duration from increasing. Shocks can be aborted when …
The use of signal analyses of ventricular tachycardia electrograms to predict the response of antitachycardia pacing in patients with implantable cardioverter …
… The implantable cardioverter-defibrillator (ICD) is now a … the ATP during or before charging
was not applied in this study. … “when to use more or less ATP in a VT zone” as an optimal …
was not applied in this study. … “when to use more or less ATP in a VT zone” as an optimal …
Permanent antitachycardia pacemaker therapy for ventricular tachycardia
DM Newman, MA Lee, JM Herre… - Pacing and Clinical …, 1989 - Wiley Online Library
… , the automatic implantable cardioverter defibrillator (AICD] has … However, antitachycardia
pacing in the ventricle can lead to … the optimal tachycardia detection and pacing parameters, …
pacing in the ventricle can lead to … the optimal tachycardia detection and pacing parameters, …
The implantable cardioverter–defibrillator
ME Field, MR Gold - Cardiac Pacing and ICDs, 2020 - Wiley Online Library
… ‐threatening arrhythmias (ie ventricular tachycardia or fibrillation) … Antitachycardia pacing is
delivered at the end of the top … The optimal sensing vector minimizes the likelihood of double …
delivered at the end of the top … The optimal sensing vector minimizes the likelihood of double …
Antitachycardia pacing for reduction of implantable cardioverter-defibrillator shocks
DJ Cantillon, BL Wilkoff - Heart Rhythm, 2015 - Elsevier
… and secondary implantable cardioverter-defibrillator recipients. … over ICD shocks in treating
fast ventricular tachycardia (VT) … B: ATP during charging for a rapid monomorphic VT (CL ~…
fast ventricular tachycardia (VT) … B: ATP during charging for a rapid monomorphic VT (CL ~…