[HTML][HTML] Uterine artery embolization with highly compressible calibrated microspheres for the treatment of uterine fibroids

D Szejnfeld, RFT Santos, AM Kambara… - Radiologia …, 2022 - SciELO Brasil
highly compressible calibrated microspheres in uterine artery embolization (UAE) for the
treatment of uterine … Polifit 70 microspheres showed satisfactory results for the treatment of …

Comparison of embolic agents used in uterine artery embolisation: a systematic review and meta-analysis

R Das, R Champaneria, JP Daniels… - Cardiovascular and …, 2014 - Springer
microspheres (TAGM) are calibrated microspheres and are widely regarded as a highly
effective uterine embolic … The spheres are compressible, which allow easy passage through a …

Microspheres and nonspherical particles for embolization

A Laurent - Techniques in vascular and interventional radiology, 2007 - Elsevier
uterine arteries embolization, Pelage and coworkers 4 has shown that calibrated microspheres
… SE is very compressible and can flatten with no resistance at very low compression force.…

Review of the development of methods for characterization of microspheres for use in embolotherapy: translating bench to cathlab

M Caine, D Carugo, X Zhang, M Hill… - Advanced …, 2017 - Wiley Online Library
… is observed in vivo as microsphere compressibility is also an … embolic agent that failed to
work clinically in the treatment of … elicit a calibrated physical restriction is heavily determined by …

Arterial distribution of calibrated tris-acryl gelatin and polyvinyl alcohol embolization microspheres in sheep uterus

A Laurent, M Wassef, J Namur, H Ghegediban… - Cardiovascular and …, 2010 - Springer
… two types of microspheres in uterine fibroid embolization. … PVAMS is a very compressible
material that behaves as a … reduction in fibroid enhancement among patients treated with …

[HTML][HTML] Advances in degradable embolic microspheres: a state of the art review

J Doucet, L Kiri, K O'Connell, S Kehoe… - Journal of functional …, 2018 - mdpi.com
… A variety of tightly calibrated particle size distributions—to … by the compressibility of the control
microspheres [24], which … joining the uterine artery with the vaginal and ovarian arteries [25…

Limited uterine artery embolization for leiomyomas with tris-acryl gelatin microspheres: 1-year follow-up

PNM Lohle, FP Boekkooi, AJ Smeets… - Journal of vascular and …, 2006 - Elsevier
… Targeted UAE using large calibrated microspheres is safe … In this study with prospective
data collection and a high rate of … The compressibility of the microspheres made microcatheter …

[HTML][HTML] Embolização de miomas uterinos com microesferas calibradas de alta compressibilidade

D Szejnfeld, RFT Santos, AM Kambara… - Radiologia …, 2022 - rb.org.br
… OBJECTIVE: To evaluate the safety and efficacy of using highly compressible calibrated
microspheres in uterine artery embolization (UAE) for the treatment of uterine fibroids. …

Uterine artery embolization: a safe and effective, minimally invasive, uterine-sparing treatment option for symptomatic fibroids

NJ Vo, RT Andrews - Seminars in interventional radiology, 2008 - thieme-connect.com
… Tris-acryl gelatin microspheres, approved by the US Food and Drug Administration (FDA) …
embolic particles that are calibrated for a more consistent size. They are slightly compressible

Uterine artery embolisation for symptomatic adenomyosis with polyzene F-coated hydrogel microspheres: three-year clinical follow-up using UFS–QoL questionnaire

RJ Nijenhuis, AJ Smeets, M Morpurgo… - Cardiovascular and …, 2015 - Springer
… these microspheres is the availability of exact size calibration. In … agents, with smooth surfaces,
slightly compressible and elastic … embolic agent is color-coded for each size, thus highly