Accelerating breast MRI acquisition with generative AI models
A Okolie, T Dirrichs, LC Huck, S Nebelung… - European …, 2024 - Springer
European Radiology, 2024•Springer
Objectives To investigate the use of the score-based diffusion model to accelerate breast
MRI reconstruction. Materials and methods We trained a score-based model on 9549 MRI
examinations of the female breast and employed it to reconstruct undersampled MRI images
with undersampling factors of 2, 5, and 20. Images were evaluated by two experienced
radiologists who rated the images based on their overall quality and diagnostic value on an
independent test set of 100 additional MRI examinations. Results The score-based model …
MRI reconstruction. Materials and methods We trained a score-based model on 9549 MRI
examinations of the female breast and employed it to reconstruct undersampled MRI images
with undersampling factors of 2, 5, and 20. Images were evaluated by two experienced
radiologists who rated the images based on their overall quality and diagnostic value on an
independent test set of 100 additional MRI examinations. Results The score-based model …
Objectives
To investigate the use of the score-based diffusion model to accelerate breast MRI reconstruction.
Materials and methods
We trained a score-based model on 9549 MRI examinations of the female breast and employed it to reconstruct undersampled MRI images with undersampling factors of 2, 5, and 20. Images were evaluated by two experienced radiologists who rated the images based on their overall quality and diagnostic value on an independent test set of 100 additional MRI examinations.
Results
The score-based model produces MRI images of high quality and diagnostic value. Both T1- and T2-weighted MRI images could be reconstructed to a high degree of accuracy. Two radiologists rated the images as almost indistinguishable from the original images (rating 4 or 5 on a scale of 5) in 100% (radiologist 1) and 99% (radiologist 2) of cases when the acceleration factor was 2. This fraction dropped to 88% and 70% for an acceleration factor of 5 and to 5% and 21% with an extreme acceleration factor of 20.
Conclusion
Score-based models can reconstruct MRI images at high fidelity, even at comparatively high acceleration factors, but further work on a larger scale of images is needed to ensure that diagnostic quality holds.
Clinical relevance statement
The number of MRI examinations of the breast is expected to rise with MRI screening recommended for women with dense breasts. Accelerated image acquisition methods can help in making this examination more accessible.
Key Points
- Accelerating breast MRI reconstruction remains a significant challenge in clinical settings.
- Score-based diffusion models can achieve near-perfect reconstruction for moderate undersampling factors.
- Faster breast MRI scans with maintained image quality could revolutionize clinic workflows and patient experience.
Springer
以上显示的是最相近的搜索结果。 查看全部搜索结果