Antibody-based sensors for heavy metal ions
DA Blake, RM Jones, RC Blake II, AR Pavlov… - Biosensors and …, 2001 - Elsevier
DA Blake, RM Jones, RC Blake II, AR Pavlov, IA Darwish, H Yu
Biosensors and Bioelectronics, 2001•ElsevierCompetitive immunoassays for Cd (II), Co (II), Pb (II) and U (VI) were developed using
identical reagents in two different assay formats, a competitive microwell format and an
immunosensor format with the KinExA™ 3000. Four different monoclonal antibodies specific
for complexes of EDTA–Cd (II), DTPA–Co (II), 2, 9-dicarboxyl-1, 10-phenanthroline–U (VI),
or cyclohexyl–DTPA–Pb (II) were incubated with the appropriate soluble metal–chelate
complex. In the microwell assay format, the immobilized version of the metal–chelate …
identical reagents in two different assay formats, a competitive microwell format and an
immunosensor format with the KinExA™ 3000. Four different monoclonal antibodies specific
for complexes of EDTA–Cd (II), DTPA–Co (II), 2, 9-dicarboxyl-1, 10-phenanthroline–U (VI),
or cyclohexyl–DTPA–Pb (II) were incubated with the appropriate soluble metal–chelate
complex. In the microwell assay format, the immobilized version of the metal–chelate …
Competitive immunoassays for Cd(II), Co(II), Pb(II) and U(VI) were developed using identical reagents in two different assay formats, a competitive microwell format and an immunosensor format with the KinExA™ 3000. Four different monoclonal antibodies specific for complexes of EDTA–Cd(II), DTPA–Co(II), 2,9-dicarboxyl-1,10-phenanthroline–U(VI), or cyclohexyl–DTPA–Pb(II) were incubated with the appropriate soluble metal–chelate complex. In the microwell assay format, the immobilized version of the metal–chelate complex was present simultaneously in the assay mixture. In the KinExA format, the antibody was allowed to pre-equilibrate with the soluble metal-chelate complex, then the incubation mixture was rapidly passed through a microcolumn containing the immobilized metal-chelate complex. In all four assays, the KinExA format yielded an assay with 10–1000-fold greater sensitivity. The enhanced sensitivity of the KinExA format is most likely due to the differences in the affinity of the monoclonal antibodies for the soluble versus the immobilized metal–chelate complex. The KinExA 3000 instrument and the Cd(II)-specific antibody were used to construct a prototype assay that could correctly assess the concentration of cadmium spiked into a groundwater sample. Mean analytical recovery of added Cd(II) was 114.25±11.37%. The precision of the assay was satisfactory; coefficients of variation were 0.81–7.77% and 3.62–14.16% for within run and between run precision, respectively.
Elsevier