Liquid cooling of data centers: A necessity facing challenges
M Azarifar, M Arik, JY Chang - Applied Thermal Engineering, 2024 - Elsevier
… water cooling adaptation for reducing the power consumption of … with cooling systems that
consume up to 40 % of total energy in … system must also be provided since liquid‐cooled racks …
consume up to 40 % of total energy in … system must also be provided since liquid‐cooled racks …
[PDF][PDF] Minimizing Power Consumption At Module, Server And Rack-levels Within A Data Center Through Design And Energy-efficient Operation Of Dynamic Cooling …
JE Fernandes - 2015 - mavmatrix.uta.edu
… In addition to growth in the industry, power densities continue to rise in IT equipment …
Cooling systems account for around a third of overall power consumption requiring more energy…
Cooling systems account for around a third of overall power consumption requiring more energy…
Rack-level Cooling Technologies for Data Centers–A Comprehensive Review
… energy consumption issue of data center cooling systems has … liquid-cooled data centers:
From chip to the cooling system … To reduce energy consumption, how to adjust the fan speed …
From chip to the cooling system … To reduce energy consumption, how to adjust the fan speed …
Maximizing Cooling Potential: A Step-by-Step Guide to Commissioning Liquid-Cooled Data Centers
… cooling methods to minimize thermal resistance and enhance … noise due to fans and power
consumption also increases. In … representation of a data center and a liquid cooled rack. …
consumption also increases. In … representation of a data center and a liquid cooled rack. …
Data center power consumption reductions achievable with liquid cooling: A case study
DC Hwang - 2009 - search.proquest.com
… The model is applied to a single rack system that can be … Minimizing pumping power, pressure
drop, and space utilized by a … water loop to go into and out of the liquid cooled electronics. …
drop, and space utilized by a … water loop to go into and out of the liquid cooled electronics. …
Server liquid cooling with chiller-less data center design to enable significant energy savings
… a 15 kW rack fully populated with liquid cooled servers. This … the system thermal performance
and energy usage using … The obj ective of this project is to reduce the cooling energy …
and energy usage using … The obj ective of this project is to reduce the cooling energy …
Review on electronics cooling systems
… Recently, heat dissipation and the power consumption are the … Rack-based cooling systems
support power density up to 50 … cooling technology is the fully immersed direct liquid-cooled …
support power density up to 50 … cooling technology is the fully immersed direct liquid-cooled …
Experimental Study Demonstrating Pumping Power Savings at Rack Level Using Dynamic Cooling
… the cooling power consumption as a percentage of total IT … The cooling power savings
reduce with an increase in inlet … further improve energy savings in liquid-cooled data centers. …
reduce with an increase in inlet … further improve energy savings in liquid-cooled data centers. …
A METHODOLOGY FOR THERMAL CHARACTERIZATION OF HIGH-POWER LIQUID-COOLED SERVERS
… efficient, and minimizes downtime. In this study, a proposed … to continuously increasing
power densities at rack-level. The … the total energy consumed towards equipment cooling only. …
power densities at rack-level. The … the total energy consumed towards equipment cooling only. …
Data Centers Cooling: A Critical Review of Techniques, Challenges, and Energy Saving Solutions.
… , underlining their role in reducing energy consumption and … pipes for the CRAC and
liquid-cooled racks inside of the … to reduce the cooling system's energy consumption by using …
liquid-cooled racks inside of the … to reduce the cooling system's energy consumption by using …