Liquid cooling of data centers: A necessity facing challenges

M Azarifar, M Arik, JY Chang - Applied Thermal Engineering, 2024 - Elsevier
… water cooling adaptation for reducing the power consumption of … with cooling systems that
consume up to 40 % of total energy in … system must also be provided since liquidcooled racks

[PDF][PDF] Minimizing Power Consumption At Module, Server And Rack-levels Within A Data Center Through Design And Energy-efficient Operation Of Dynamic Cooling …

JE Fernandes - 2015 - mavmatrix.uta.edu
… In addition to growth in the industry, power densities continue to rise in IT equipment
Cooling systems account for around a third of overall power consumption requiring more energy

Rack-level Cooling Technologies for Data Centers–A Comprehensive Review

X Li, M Li, Y Zhang, Z Han, S Wang - Journal of Building Engineering, 2024 - Elsevier
energy consumption issue of data center cooling systems has … liquid-cooled data centers:
From chip to the cooling system … To reduce energy consumption, how to adjust the fan speed …

Maximizing Cooling Potential: A Step-by-Step Guide to Commissioning Liquid-Cooled Data Centers

P Shahi, A Heydari, H Modi… - … Electronic Systems  …, 2024 - ieeexplore.ieee.org
cooling methods to minimize thermal resistance and enhance … noise due to fans and power
consumption also increases. In … representation of a data center and a liquid cooled rack. …

Data center power consumption reductions achievable with liquid cooling: A case study

DC Hwang - 2009 - search.proquest.com
… The model is applied to a single rack system that can be … Minimizing pumping power, pressure
drop, and space utilized by a … water loop to go into and out of the liquid cooled electronics. …

Server liquid cooling with chiller-less data center design to enable significant energy savings

M Iyengar, M David, P Parida, V Kamath… - 2012 28th annual …, 2012 - ieeexplore.ieee.org
… a 15 kW rack fully populated with liquid cooled servers. This … the system thermal performance
and energy usage using … The obj ective of this project is to reduce the cooling energy

Review on electronics cooling systems

CMA Kumar, PCM Kumar - Advances in Natural and Applied Sciences, 2017 - go.gale.com
… Recently, heat dissipation and the power consumption are the … Rack-based cooling systems
support power density up to 50 … cooling technology is the fully immersed direct liquid-cooled

Experimental Study Demonstrating Pumping Power Savings at Rack Level Using Dynamic Cooling

P Shahi, S Saini, P Bansode… - Journal of Enhanced …, 2022 - dl.begellhouse.com
… the cooling power consumption as a percentage of total IT … The cooling power savings
reduce with an increase in inlet … further improve energy savings in liquid-cooled data centers. …

A METHODOLOGY FOR THERMAL CHARACTERIZATION OF HIGH-POWER LIQUID-COOLED SERVERS

P Shahi, A Heydari, S Saini, P Bansode… - Heat Transfer …, 2024 - dl.begellhouse.com
… efficient, and minimizes downtime. In this study, a proposed … to continuously increasing
power densities at rack-level. The … the total energy consumed towards equipment cooling only. …

Data Centers Cooling: A Critical Review of Techniques, Challenges, and Energy Saving Solutions.

AA Alkrush, MS Salem, O Abdelrehim… - … Journal of Refrigeration, 2024 - Elsevier
… , underlining their role in reducing energy consumption and … pipes for the CRAC and
liquid-cooled racks inside of the … to reduce the cooling system's energy consumption by using …