Experimental simulation of simultaneous vision
P de Gracia, C Dorronsoro… - … & visual science, 2013 - iovs.arvojournals.org
Investigative ophthalmology & visual science, 2013•iovs.arvojournals.org
Purpose.: To present and validate a prototype of an optical instrument that allows
experimental simulation of pure bifocal vision. To evaluate the influence of different power
additions on image contrast and visual acuity. Methods.: The instrument provides the eye
with two superimposed images, aligned and with the same magnification, but with different
defocus states. Subjects looking through the instrument are able to experience pure
simultaneous vision, with adjustable refractive correction and addition power. The …
experimental simulation of pure bifocal vision. To evaluate the influence of different power
additions on image contrast and visual acuity. Methods.: The instrument provides the eye
with two superimposed images, aligned and with the same magnification, but with different
defocus states. Subjects looking through the instrument are able to experience pure
simultaneous vision, with adjustable refractive correction and addition power. The …
Abstract
Purpose.: To present and validate a prototype of an optical instrument that allows experimental simulation of pure bifocal vision. To evaluate the influence of different power additions on image contrast and visual acuity.
Methods.: The instrument provides the eye with two superimposed images, aligned and with the same magnification, but with different defocus states. Subjects looking through the instrument are able to experience pure simultaneous vision, with adjustable refractive correction and addition power. The instrument is used to investigate the impact of the amount of addition of an ideal bifocal simultaneous vision correction, both on image contrast and on visual performance. The instrument is validated through computer simulations of the letter contrast and by equivalent optical experiments with an artificial eye (camera). Visual acuity (VA) was measured in four subjects (age: 34.3±3.4 years; spherical error:− 2.1±2.7 diopters [D]) for low and high contrast letters and different amounts of addition.
Results.: The largest degradation in contrast and visual acuity (∼ 25%) occurred for additions around±2 D, while additions of±4 D produced lower degradation (14%). Low additions (1–2 D) result in lower VA than high additions (3–4 D).
Conclusions.: A simultaneous vision instrument is an excellent tool to simulate bifocal vision and to gain understanding of multifocal solutions for presbyopia. Simultaneous vision induces a pattern of visual performance degradation, which is well predicted by the degradation found in image quality. Neural effects, claimed to be crucial in the patients' tolerance of simultaneous vision, can be therefore compared with pure optical effects.