High resolution x-ray transition-edge sensor cooled by tunnel junction refrigerators

NA Miller, GC O'Neil, JA Beall, GC Hilton… - Applied Physics …, 2008 - pubs.aip.org
… demonstrate cooling of an x-ray transition-edge sensor (TES) using solid-state refrigerators
… have demonstrated successful cooling of a high-resolution x-ray TES using NIS refrigerators, …

Operation of an X-ray transition-edge sensor cooled by tunnel junction refrigerators

NA Miller, JA Beall, GC Hilton, KD Irwin… - Journal of Low …, 2008 - Springer
… demonstrate successful cooling of an X-ray transition-edge sensor (TES) using solid-state
refrigerators based on normal-metal/insulator/superconductor (NIS) tunnel junctions. Above …

[图书][B] Transition-edge sensors for X-ray astronomy

SP Trowell - 2001 - search.proquest.com
… consideration is the Superconducting Tunnel Junction (STJ). … of the refrigerator and
associated X-ray beamline are … helium dilution refrigerator with a cooling power specification …

[PDF][PDF] Transition-edge sensor array development

M Palosaari - 2009 - jyx.jyu.fi
… in X-ray absorption spectroscopy and our X-ray detectors … balance the cooling power of
the refrigerator available from the … of the art adiabatic demagnetization refrigerator (ADR) that …

[图书][B] Development of transition edge sensor distributed read-out imaging devices for applications in x-ray astronomy

SJ Smith - 2006 - search.proquest.com
… need for using cryogenically-cooled focal plane detectors. … generation as well as the
tunnelling statistics and scales as … We also discuss Dilution Refrigerators (DRs) required for TES …

[HTML][HTML] Transition Edge Sensors: Physics and Applications

M De Lucia, P Dal Bo, E Di Giorgi, T Lari, C Puglia… - Instruments, 2024 - mdpi.com
… TES arrays see a wide application as X-ray detectors; their … The energy gap can be measured
through electron tunnel … ) that contributes to cooling down the TES after detection, L is the …

[图书][B] Microcalorimetry and the transition-edge sensor

MA Lindeman - 2000 - search.proquest.com
… The detector eventually cools back to equilibrium. ready to … They are being developed as
broadband x-ray detectors by our … superconducting electrical wires are used in our refrigerators

Using electron-tunneling refrigerators to cool electrons, membranes, and sensors

NA Miller - 2008 - search.proquest.com
… , Operation of an X-ray transition-edge sensor cooled by tunnel junction refrigerators, J. Low
… GC, Schmidt DR, Vale LR, Ullom JN, High resolution X-ray transition-edge sensor cooled by …

[PDF][PDF] Transition-edge sensor imaging arrays for astrophysics applications

JA Burney - 2007 - jaburney.com
refrigerators, and even cryogen-free pulse-tube cooled systems, … Superconducting Tunnel
Junctions (STJs) utilize the ability of … of phonon-mediated TESs for X-ray applications, see [36]. …

Cryogenic detectors and their application to X-ray fluorescence analysis

M Frank, S Friedrich, J Höhne… - Journal of X-Ray …, 2003 - content.iospress.com
… are transition edge sensors (TESs) and NIS tunnel junctions (… cryogenic detector systems
that provide sufficient refrigeration … Using a pulse tube refrigerator, the cooling time from room …