Innovative test method for the shielding effectiveness measurement of conductive thin films in a wide frequency range
MS Sarto, A Tamburrano - IEEE Transactions on …, 2006 - ieeexplore.ieee.org
IEEE Transactions on Electromagnetic Compatibility, 2006•ieeexplore.ieee.org
This paper presents an innovative test procedure for the prediction of the shielding
effectiveness of small sample materials, consisting of a dielectric substrate coated with thin
conducting film, in a wide frequency range up to 8 GHz. The proposed technique overcomes
the limitations of the ASTM D4935 test method concerning the upper operating frequency
and the required minimum specimen dimensions. A new high-order equivalent circuit model
of the test fixture is developed. A correction factor is applied to the measured insertion loss to …
effectiveness of small sample materials, consisting of a dielectric substrate coated with thin
conducting film, in a wide frequency range up to 8 GHz. The proposed technique overcomes
the limitations of the ASTM D4935 test method concerning the upper operating frequency
and the required minimum specimen dimensions. A new high-order equivalent circuit model
of the test fixture is developed. A correction factor is applied to the measured insertion loss to …
This paper presents an innovative test procedure for the prediction of the shielding effectiveness of small sample materials, consisting of a dielectric substrate coated with thin conducting film, in a wide frequency range up to 8 GHz. The proposed technique overcomes the limitations of the ASTM D4935 test method concerning the upper operating frequency and the required minimum specimen dimensions. A new high-order equivalent circuit model of the test fixture is developed. A correction factor is applied to the measured insertion loss to eliminate both the resonance peak below cutoff appearing in the high-frequency range and the low-frequency errors due to the weak capacitive coupling between the flanges of the coaxial cell. The accurate prediction of the shielding effectiveness of the test material against a plane wave is then derived from the insertion loss measurements.
ieeexplore.ieee.org
以上显示的是最相近的搜索结果。 查看全部搜索结果