A study on non-invasive blood glucose estimation—An approach using capacitance measurement technique
R Periyasamy, S Anand - 2016 International Conference on …, 2016 - ieeexplore.ieee.org
… From figure 4 it is clear that capacitance measured reaches initial … capacitance measurement
is a direct measure of blood glucose. It is well known that skin parameters eg thicknesses of …
is a direct measure of blood glucose. It is well known that skin parameters eg thicknesses of …
Comparison of invasive and non-invasive cylindrical capacitive sensors for electrical measurements of different water solutions and mixtures
… non-invasive cylindrical capacitive sensor (CCS) designs for the electrical measurements of
… Because of the glass tube, thickness the filling gap volume is decreased in this arrangement …
… Because of the glass tube, thickness the filling gap volume is decreased in this arrangement …
Real-time monitoring and measurement of wax deposition in pipelines via non-invasive electrical capacitance tomography
ILS Mei, I Ismail, A Shafquet… - Measurement Science …, 2015 - iopscience.iop.org
… , a non-invasive/non-intrusive electrical capacitance tomography (ECT) system has been
applied to provide real-time visualization of the formation of paraffin waxes and to measure the …
applied to provide real-time visualization of the formation of paraffin waxes and to measure the …
A wearable CMOS impedance to frequency sensing system for non-invasive impedance measurements
A Hedayatipour, S Aslanzadeh… - … Circuits and Systems, 2020 - ieeexplore.ieee.org
… In our design, since the tissue is modeled mostly as a capacitance, we only considered
capacitive measurements. In the … The pulse width associated with the resistance or capacitance …
capacitive measurements. In the … The pulse width associated with the resistance or capacitance …
Capacitive determination of wall-film thickness in liquid-liquid slug flow and its application as a non-invasive microfluidic viscosity sensor
L Arsenjuk, M Wiesehahn, EM Zimmermann… - Sensors and Actuators A …, 2020 - Elsevier
… the measurement … film thickness measured by employing well-known correlations. In this
study, a methodology to ascertain wall film thickness from capacitive impedance measurements …
study, a methodology to ascertain wall film thickness from capacitive impedance measurements …
Electrical capacitance as a rapid and non-invasive indicator of root length
TW Ellis, W Murray, K Paul, L Kavalieris… - Tree …, 2013 - academic.oup.com
… Sample depth was determined by the limit of most coarse (>0.001 m radius) roots and … Root
fresh densities ρ were not measured but were calculated using root moisture content for each …
fresh densities ρ were not measured but were calculated using root moisture content for each …
[PDF][PDF] Liquid film thickness estimation using electrical capacitance tomography
Z Cui, C Yang, B Sun, H Wang - Measurement Science Review, 2014 - sciendo.com
… Capacitance measurements are made from an externally mounted electrode array in a
non-invasive … Both average and distributed oil film thicknesses can be calculated from the …
non-invasive … Both average and distributed oil film thicknesses can be calculated from the …
Review of non-invasive continuous glucose monitoring based on impedance spectroscopy
J Huang, Y Zhang, J Wu - Sensors and Actuators A: Physical, 2020 - Elsevier
… Capacitive sensors work by measuring permittivity changes in the medium when the
interrogating electric fields pass through it. … array is within 20 mm and the width is within 15 mm. …
interrogating electric fields pass through it. … array is within 20 mm and the width is within 15 mm. …
Non-invasive blood sugar detection by cost-effective capacitance spectroscopy
… of any interdigital electrodes requires solving analytical equations and depends on many
parameters such as electrode finger size, length, thickness, spacing, and material. To keep the …
parameters such as electrode finger size, length, thickness, spacing, and material. To keep the …
A non-invasive capacitive sensor strip for aerodynamic pressure measurement
M Zagnoni, A Golfarelli, S Callegari, A Talamelli… - Sensors and Actuators A …, 2005 - Elsevier
… This paper presents a capacitive pressure sensor strip implemented in general purpose …
The device length and width can be set according to the application: the measurements and …
The device length and width can be set according to the application: the measurements and …