On-line determination of Sb (III) and total Sb using baker's yeast immobilized on polyurethane foam and hydride generation inductively coupled plasma optical …
Spectrochimica Acta Part B: Atomic Spectroscopy, 2006•Elsevier
The yeast Saccharomyces cerevisiae was immobilized in cubes of polyurethane foam and
the ability of this immobilized material to separate Sb (III) and Sb (V) was investigated. A
method based on sequential determination of total Sb (after on-line reduction of Sb (V) to Sb
(III) with thiourea) and Sb (III)(after on-line solid–liquid phase extraction) by hydride
generation inductively coupled plasma optical emission spectrometry is proposed. A flow
system assembled with solenoid valves was used to manage all stages of the process. The …
the ability of this immobilized material to separate Sb (III) and Sb (V) was investigated. A
method based on sequential determination of total Sb (after on-line reduction of Sb (V) to Sb
(III) with thiourea) and Sb (III)(after on-line solid–liquid phase extraction) by hydride
generation inductively coupled plasma optical emission spectrometry is proposed. A flow
system assembled with solenoid valves was used to manage all stages of the process. The …
The yeast Saccharomyces cerevisiae was immobilized in cubes of polyurethane foam and the ability of this immobilized material to separate Sb(III) and Sb(V) was investigated. A method based on sequential determination of total Sb (after on-line reduction of Sb(V) to Sb(III) with thiourea) and Sb(III) (after on-line solid–liquid phase extraction) by hydride generation inductively coupled plasma optical emission spectrometry is proposed. A flow system assembled with solenoid valves was used to manage all stages of the process. The effects of pH, sample loading and elution flow rates on solid–liquid phase extraction of Sb(III) were evaluated. Also, the parameters related to on-line pre-reduction (reaction coil and flow rates) were optimized. Detection limits of 0.8 and 0.15 μg L−1 were obtained for total Sb and Sb(III), respectively. The proposed method was applied to the analysis of river water and effluent samples. The results obtained for the determination of total Sb were in agreement with expected values, including the river water Standard Reference Material 1640 certified by the National Institute of Standards and Technology (NIST). Recoveries of Sb(III) and Sb(V) in spiked samples were between 81±19 and 111±15% when 120 s of sample loading were used.
Elsevier
以上显示的是最相近的搜索结果。 查看全部搜索结果