Patient-specific quality assurance for the delivery of 60Co intensity modulated radiation therapy subject to a 0.35-T lateral magnetic field

HH Li, VL Rodriguez, OL Green, Y Hu… - … Journal of Radiation …, 2015 - Elsevier
… This work describes a patient-specific dosimetry quality assurance (QA) program for …
We developed a patient-specific intensity modulated radiation therapy quality assurance (QA) …

Development and validation of a comprehensive patientspecific quality assurance program for a novel stereotactic radiation delivery system for breast lesions

SJ Becker, Y Niu, Y Mutaf, S Chen… - Journal of Applied …, 2019 - Wiley Online Library
… cobalt-60 ( 60 Co) sources dynamically paint dose to a … in three axes during beam delivery.
From simulation to treatment… ) commonly used in intensity-modulated radiation therapy. In the …

Quality of intensity modulated radiation therapy treatment plans using a 60Co magnetic resonance image guidance radiation therapy system

HO Wooten, O Green, M Yang, T DeWees… - … Journal of Radiation …, 2015 - Elsevier
… using physician-specified patient-specific target coverage and … the higher HI, 1 quality control
procedure in our plan review … In conclusion, an IMRT delivery system using 60 Co sources …

Poster

N Sekar, B Ganesan, HRA Sahib… - Journal of Medical …, 2018 - journals.lww.com
… device in radiotherapy treatment quality assurance (QA), due … is a suitable device for
patient-specific pretreatment QA to verify … orientation in Intensity modulated radiation therapy and …

Poster

S Sahoo, S Vandana, R Kumar, TP Selvam… - Journal of Medical …, 2018 - journals.lww.com
… device in radiotherapy treatment quality assurance (QA), due … is a suitable device for
patient-specific pretreatment QA to verify … orientation in Intensity modulated radiation therapy and …

Poster

S Mishra, TP Selvam - Journal of Medical Physics, 2018 - journals.lww.com
… device in radiotherapy treatment quality assurance (QA), due … is a suitable device for
patient-specific pretreatment QA to verify … orientation in Intensity modulated radiation therapy and …

A management method for the statistical results of patient-specific quality assurance for intensity-modulated radiation therapy

S Nakamura, H Okamoto, A Wakita… - Journal of Radiation …, 2017 - academic.oup.com
intensity-modulated delivery techniques used were sliding window IMRT and volumetric-modulated
dose to water for reference beam quality, using 60 Co gamma-rays according to …

Commissioning of an Upgraded Equinox-100 Cobalt-60 Radiation Therapy Unit in the Varian Eclipse Treatment Planning System

TN Bulenga - 2019 - search.proquest.com
patient specific dose calculations and determine the optimal and practicable treatment plan
to be delivered … dose delivery techniques such as intensity modulated radiation therapy (IMRT…

Film dosimetry studies for patient specific quality assurance in microbeam radiation therapy

A Ocadiz, J Livingstone, M Donzelli, S Bartzsch… - Physica Medica, 2019 - Elsevier
… In preclinical trials we investigate whether MRT can also be delivered as a dose-boost in an
… dose to water in 60 Co and TH200 beam qualities. The TH200 beam quality, with average …

[PDF][PDF] Commissioning and Quality Assurance of Computerized Planning Systems for Radiation Treatment of Cancer

C Planning - international.anl.gov
… ; and (c) radiation dose delivery using relatively simple 60Co … with MLCs, to intensity modulated
radiation therapies (IMRTs); (b) … (ongoing) tests and patient specific QA, and Section 12 …