Performance of the Xpert® MTB/RIF assay in an active case-finding strategy: a pilot study from Tanzania

EN Ntinginya, SB Squire, KA Millington… - … of tuberculosis and …, 2012 - ingentaconnect.com
EN Ntinginya, SB Squire, KA Millington, B Mtafya, E Saathoff, N Heinrich, G Rojas-Ponce…
The International journal of tuberculosis and lung disease, 2012ingentaconnect.com
In this pilot study, we evaluated the Xpert® MTB/RIF assay in an active case-finding strategy,
using two spot sputum samples collected within a 1-hour interval from household contacts of
smear-positive TB index cases. Tuberculosis (TB) confirmed by culture served as the
reference standard. Among 219 enrolled contacts, the yield of active TB was 2.3%. While the
sensitivity of smear microscopy was 60%(95% CI 14.7–94.7), Xpert MTB/RIF achieved a
sensitivity of 100%(95% CI 47.81–100.0). All culture-confirmed cases tested positive by …
In this pilot study, we evaluated the Xpert® MTB/RIF assay in an active case-finding strategy, using two spot sputum samples collected within a 1-hour interval from household contacts of smear-positive TB index cases. Tuberculosis (TB) confirmed by culture served as the reference standard. Among 219 enrolled contacts, the yield of active TB was 2.3%. While the sensitivity of smear microscopy was 60% (95%CI 14.7–94.7), Xpert MTB/RIF achieved a sensitivity of 100% (95%CI 47.81–100.0). All culture-confirmed cases tested positive by Xpert MTB/RIF on the first submitted sample, suggesting that the evaluation of only one sample could be sufficient for TB diagnosis in this context.
ingentaconnect.com
以上显示的是最相近的搜索结果。 查看全部搜索结果