Study protocol: PoPE-prediction of preterm delivery by electrohysterography

H de Lau, C Rabotti, HP Oosterbaan, M Mischi… - BMC pregnancy and …, 2014 - Springer
H de Lau, C Rabotti, HP Oosterbaan, M Mischi, GS Oei
BMC pregnancy and childbirth, 2014Springer
Background Traditional methods used for prediction of preterm delivery are subjective and
inaccurate. The Electrohysterogram (EHG) and in particular the estimation of the EHG
conduction velocity, is a relatively new promising method for detecting imminent preterm
delivery. To date the analysis of the conduction velocity has relied on visual inspection of the
signals. As a next step towards the introduction of EHG analysis as a clinical tool, we
propose an automated method for EHG conduction velocity estimation for both the speed …
Background
Traditional methods used for prediction of preterm delivery are subjective and inaccurate. The Electrohysterogram (EHG) and in particular the estimation of the EHG conduction velocity, is a relatively new promising method for detecting imminent preterm delivery. To date the analysis of the conduction velocity has relied on visual inspection of the signals. As a next step towards the introduction of EHG analysis as a clinical tool, we propose an automated method for EHG conduction velocity estimation for both the speed and direction of single spike propagation.
Methods/Design
The study design will be an observational cohort study. 100 pregnant women, gestational age between 23 + 5 and 34 weeks, admitted for threatening preterm labor or preterm prelabor rupture of membranes, will be included. The length of the cervical canal will be measured by transvaginal ultrasound. The EHG will be recorded using 4 electrodes in a fixed configuration. Contractions will be detected by analysis of the EHG and using an estimation of the intra uterine pressure. In the selected contractions, the delays between channels will be estimated by cross-correlation, and subsequently, the average EHG conduction velocity will be derived. Patients will be classified as labor group and non-labor group based on the time between measurement and delivery. The average conduction velocity and cervical length will be compared between the groups. The main study endpoints will be sensitivity, specificity, and area under the ROC curve for delivery within 1,2,4,7, and 14 days from the measurement.
Discussion
In this study, the diagnostic accuracy of EHG conduction velocity analysis will be evaluated for detecting preterm labor. Visual and automatic detection of contractions will be compared. Planar wave propagation will be assumed for the calculation of the CV vector.
Trial registration
Current Controlled Trials ISRCTN07603227 .