Control techniques of dispersed generators to improve the continuity of electricity supply
… communication of control signals between the generators. The control technique is described
… If the connected load is too large to be supplied by the DG sources, the maximum power …
… If the connected load is too large to be supplied by the DG sources, the maximum power …
An overview on doubly fed induction generators′ controls and contributions to wind based electricity generation
AABM Zin, MP HA, AB Khairuddin… - … and Sustainable Energy …, 2013 - Elsevier
… electricity demand is being supplied by hydro powers. … control method provides the ability
of operation speed change over the range of 2–5%. These generators are normally connected …
of operation speed change over the range of 2–5%. These generators are normally connected …
Adaptive control system for continuity of supply using dispersed generators
S Sishuba, MA Redfern - IEE Proceedings-Generation, Transmission and …, 2005 - IET
… It consists of an expert system technique for selecting the control of the generator’s excitation
… , the reactive power that flows to and from the line connected dispersed generators tends to …
… , the reactive power that flows to and from the line connected dispersed generators tends to …
[图书][B] Distributed generation: Induction and permanent magnet generators
LL Lai, TF Chan - 2008 - books.google.com
… generator using a time-stepping coupled field-circuit method’, … is not enough energy to supply
the connected load. There are two … For generators which are connected to the distribution …
the connected load. There are two … For generators which are connected to the distribution …
Control schemes for distributed generators connected to distribution networks
W Shang, MA Redfern - 2009 44th International Universities …, 2009 - ieeexplore.ieee.org
… In this paper, the control techniques for several asynchronous generators and synchronous
… A static excitation transformer is connected and supplied from the generator output. The …
… A static excitation transformer is connected and supplied from the generator output. The …
An LPV control approach for a fuel cell power generator air supply system
D Hernández-Torres, O Sename… - 2012 American Control …, 2012 - ieeexplore.ieee.org
… can be connected to the utility grid or can be operated as stand-alone power supply systems
… In this third method, we keep the notation presented for the full reduced order LPV system (…
… In this third method, we keep the notation presented for the full reduced order LPV system (…
Self-excited induction generator research—a survey
GK Singh - Electric Power Systems Research, 2004 - Elsevier
… various issues related to the use of induction generator as … generator operation in stand-alone/isolated
mode to supply far … method of analysis of self-excited induction generator by …
mode to supply far … method of analysis of self-excited induction generator by …
Options for control of reactive power by distributed photovoltaic generators
… Despite the challenges related to accommodating PV generators, … In Section V, we review a
few control methods that have … Reactive power supplied by these generators has thus limited …
few control methods that have … Reactive power supplied by these generators has thus limited …
A multi-agent solution to distribution system management by considering distributed generators
… The maximum power supply ability for the substation is set to 100 MW, and is connected to a
50 MW generator … The conventional control techniques were no longer suitable to control an …
50 MW generator … The conventional control techniques were no longer suitable to control an …
Analysis of voltage control for a self-excited induction generator using a current-controlled voltage source inverter (CC-VSI)
SC Kuo, L Wang - IEE Proceedings-Generation, Transmission and …, 2001 - IET
… capacitor bank is appropriately connected across the terminals of … that the controlled reactive
currents, which are supplied by the … of the mains in this proposed control method, there is no …
currents, which are supplied by the … of the mains in this proposed control method, there is no …
相关搜索
- control techniques continuity of electricity supply
- control techniques doubly fed induction generators
- intelligent control methods
- distributed generators voltage control
- continuity of supply dispersed generators
- options for control distributed photovoltaic generators
- centralized control dispersed generators
- distributed generators control schemes
- angle control strategy induction generators
- photovoltaic generators adaptive var control
- analysis of voltage control induction generator
- control techniques dispersed generators
- control techniques wind energy conversion systems
- continuity of supply adaptive control system
- control strategies doubly fed induction generator
- local control distributed photovoltaic generators