The human ear canal: investigation of its suitability for monitoring photoplethysmographs and arterial oxygen saturation

K Budidha, PA Kyriacou - Physiological measurement, 2014 - iopscience.iop.org
Physiological measurement, 2014iopscience.iop.org
For the last two decades, pulse oximetry has been used as a standard procedure for
monitoring arterial oxygen saturation (SpO 2). However, SpO 2 measurements made from
extremities such as the finger, ear lobe and toes become susceptible to inaccuracies when
peripheral perfusion is compromised. To overcome these limitations, the external auditory
canal has been proposed as an alternative monitoring site for estimating SpO 2, on the
hypothesis that this central site will be better perfused. Therefore, a dual wavelength …
Abstract
For the last two decades, pulse oximetry has been used as a standard procedure for monitoring arterial oxygen saturation (SpO 2). However, SpO 2 measurements made from extremities such as the finger, ear lobe and toes become susceptible to inaccuracies when peripheral perfusion is compromised. To overcome these limitations, the external auditory canal has been proposed as an alternative monitoring site for estimating SpO 2, on the hypothesis that this central site will be better perfused. Therefore, a dual wavelength optoelectronic probe along with a processing system was developed to investigate the suitability of measuring photoplethysmographic (PPG) signals and SpO 2 in the human auditory canal. A pilot study was carried out in 15 healthy volunteers to validate the feasibility of measuring PPGs and SpO 2 from the ear canal (EC), and comparative studies were performed by acquiring the same signals from the left index finger (LIF) and the right index finger (RIF) in conditions of induced peripheral vasoconstriction (right hand immersion in ice water). Good quality baseline PPG signals with high signal-to-noise ratio were obtained from the EC, the LIF and the RIF sensors. During the ice water immersion, significant differences in the amplitude of the red and infrared PPG signals were observed from the RIF and the LIF sensors. The average drop in amplitude of red and infrared PPG signals from the RIF was 52.7% and 58.3%. Similarly, the LIF PPG signal amplitudes have reduced by 47.52% and 46.8% respectively. In contrast, no significant changes were seen in the red and infrared EC PPG amplitude measurements, which changed by+ 2.5% and− 1.2% respectively. The RIF and LIF pulse oximeters have failed to estimate accurate SpO 2 in seven and four volunteers respectively, while the EC pulse oximeter has only failed in one volunteer. These results suggest that the EC may be a suitable site for reliable monitoring of PPGs and SpO 2 s even in the presence of peripheral vasoconstriction.
iopscience.iop.org
以上显示的是最相近的搜索结果。 查看全部搜索结果