The reliability of ultrasonography in developmental dysplasia of the hip: How reliable is it in different hands?
M Müft Orak, T Onay, T Çağırmaz, C Elibol… - Indian journal of …, 2015 - Springer
M Müft Orak, T Onay, T Çağırmaz, C Elibol, FD Elibol, T Centel
Indian journal of orthopaedics, 2015•SpringerBackground Developmental dysplasia of the hip (DDH) is the most common skeletal
dysplasia. Two principal methods used in early diagnosis of DDH are clinical examination
and ultrasonographic investigation. Dogruel et al. found a low specifcity of clinical
examination in patients with DDH. Additionally, Kamath et al. stated that ultrasonography
performed by a radiologist in routine clinical practice is more reliable than physical
examination performed by the average clinician. In clinical practice, the application and …
dysplasia. Two principal methods used in early diagnosis of DDH are clinical examination
and ultrasonographic investigation. Dogruel et al. found a low specifcity of clinical
examination in patients with DDH. Additionally, Kamath et al. stated that ultrasonography
performed by a radiologist in routine clinical practice is more reliable than physical
examination performed by the average clinician. In clinical practice, the application and …
Background
Developmental dysplasia of the hip (DDH) is the most common skeletal dysplasia. Two principal methods used in early diagnosis of DDH are clinical examination and ultrasonographic investigation. Dogruel et al. found a low specifcity of clinical examination in patients with DDH. Additionally, Kamath et al. stated that ultrasonography performed by a radiologist in routine clinical practice is more reliable than physical examination performed by the average clinician. In clinical practice, the application and assessment of hip ultrasonography are completed by a single person. This assessment determines the followup of the patient. Thus, hip ultrasonography performed on the same person by different individuals under the same conditions will yield a more accurate assessment of the reliability of ultrasonographic assessment of DDH. Although inter-observer reliability was high in many previous studies of ultrasound image evaluation, reliability rates vary among studies of the application of ultrasonography.
Materials and Methods
Inter-examiner reliability of hip ultrasonography was analyzed among four investigators who separately evaluated 100 hips (50 infants). The obtained bone structure angles (α), cartilage structure angles (β), and distribution of hip types were compared among the investigators. All infants were brought to the hospital for a healthy child followup examination, according to the country’s health policy. Babies between 0 and 6 months were included in the study. Babies with any neuromuscular disorders, neural tube defects or any type of genetic anomalies were excluded from the study. The study was explained to the families of all infants and written informed consent was obtained.
Results
There was a signifcant difference in the hip type determined by the investigators with respect to a and p angles (P < 0.01, P < 0.01, P = 0.002). The average alpha measurements of the frst orthopedist, second orthopedist, frst radiologist, and second radiologist were 67.38 ± 6.24, 65.60 ± 5.84, 65.44 ± 4.59, and 62.59 ± 4.50, respectively. The average beta measurements of the frst orthopedist, second orthopedist, frst radiologist, and second radiologist were 53.85 ± 8.86, 50.74 ± 7.80, 44.77 ± 6.30, and 44.39 ± 5.81, respectively. Agreement among the results obtained by the clinicians was investigated in dual comparisons. The relative agreement according to the alpha angle ranged from 3.6% to 44.5%, and the relative concordance according to the beta angle ranged from 0.9% to 45.3%. Agreement regarding hip typing was determined to range from 19.1% to 42.6%.
Conclusion
Sonographic evaluation of the hip appears to vary depending on the investigator.