The effect of nasal surgery on continuous positive airway pressure device use and therapeutic treatment pressures: a systematic review and meta-analysis

M Camacho, M Riaz, R Capasso, CM Ruoff… - Sleep, 2015 - academic.oup.com
… The relationship between nasal surgery and its effect on continuous positive airway
pressure (CPAP) device therapeutic treatment pressures and CPAP device use has not been …

Continuous positive airway pressure: physiology and comparison of devices

S Gupta, SM Donn - Seminars in Fetal and Neonatal Medicine, 2016 - Elsevier
… , variations in mean airway pressure and external workload were considerably less with
the variable-flow device, which was also reported to be less sensitive to airway leakage [13]. …

Treatment of sleep-disordered breathing with positive airway pressure devices: technology update

KG Johnson, DC Johnson - … Devices: Evidence and Research, 2015 - Taylor & Francis
… positive pressure ventilation include bilevel positive airway pressure (BiPAP), adaptive
servoventilation (SV), and volume-assured pressure … the differences in the device types as well as …

Practice parameters for the use of autotitrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep …

TI Morgenthaler, RN Aurora, T Brown, R Zak, C Alessi… - Sleep, 2008 - academic.oup.com
… Practice parameters for the use of autotitrating continuous positive airway pressure devices
for titrating pressures and treating adult patients with obstructive sleep apnea syndrome: An …

Practice parameters for the use of continuous and bilevel positive airway pressure devices to treat adult patients with sleep-related breathing disorders

CA Kushida, MR Littner, M Hirshkowitz… - Sleep, 2006 - academic.oup.com
… Many positive airway pressure devices are commercially available. They may be equipped
with humidifiers, gradual pressure onset (ramp) settings, apnea and hypopnea detection …

Practice parameters for the use of auto-titrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep …

M Littner, M Hirshkowitz, D Davila, WMD Anderson… - Sleep, 2002 - academic.oup.com
… Recently, devices using new technology that automatically titrate positive airway pressure
(APAP) have become available. Such devices continually adjust pressure, as needed, to …

In vitro comparison of nasal continuous positive airway pressure devices for neonates

AG De Paoli, CJ Morley, PG Davis, R Lau… - Archives of Disease in …, 2002 - fn.bmj.com
… vitro of different devices used for the delivery of nasal continuous positive airway pressure
(… Flows of 4–8 litres/min were applied to the device so that the entire flow passed through the …

Respiratory event detection by a positive airway pressure device

RB Berry, CA Kushida, MH Kryger, H Soto-Calderon… - Sleep, 2012 - academic.oup.com
… Clinicians use the event detection information recorded by these PAP devices to assess …
airway pressure devices (APAP) to regulate changes in delivered pressure over a set pressure

Detection of upper airway status and respiratory events by a current generation positive airway pressure device

QY Li, RB Berry, MG Goetting, B Staley… - Sleep, 2015 - academic.oup.com
… A device-detected apnea-hypopnea index (AHI Flow ) < 10 events/h on a positive airway
pressure device is strong evidence of good treatment efficacy. Device-detected airway status …

Decreased imposed work with a new nasal continuous positive airway pressure device

JF Klausner, AY Lee, AA Hutchison - Pediatric pulmonology, 1996 - Wiley Online Library
… With each device this set-up resulted in the airway pressure being slightly greater than …
airway pressure was 5.64 cmHzO for the conventional device and 5.45 cmH20 for the new device