Thermodynamic analysis of protein interactions with biosensor technology
H Roos, R Karlsson, H Nilshans… - Journal of Molecular …, 1998 - Wiley Online Library
… The highest level of thermodynamic analysis in this investigation is to use the kinetic data
and apply transition state analysis. Table 3 and Figs 5,6,7 show the results of this …
and apply transition state analysis. Table 3 and Figs 5,6,7 show the results of this …
Thermodynamic analysis of antigen–antibody binding using biosensor measurements at different temperatures
G Zeder-Lutz, E Zuber, J Witz… - Analytical …, 1997 - Elsevier
… However, in all these studies, DHcal has been calculated from calorimetric data, ie, with the
biosensor technology, compared to the steady decrease of ln K with temperature reported by …
biosensor technology, compared to the steady decrease of ln K with temperature reported by …
Potential of biosensor technology for the characterization of interactions by quantitative affinity chromatography
DR Hall, DJ Winzor - Journal of Chromatography B: Biomedical Sciences …, 1998 - Elsevier
… biosensor technology in the broader context of their study by quantitative affinity chromatography.
The general reluctance to consider biosensor… as thermodynamic analyses of biosensor …
The general reluctance to consider biosensor… as thermodynamic analyses of biosensor …
Kinetic, equilibrium, and thermodynamic analysis of macromolecular interactions with BIACORE
DG Myszka - Methods in enzymology, 2000 - Elsevier
… extracting thermodynamic information from biosensor analysis requires van't Hoff analysis
to determine the enthalpy change. While biosensors can quantitate the amount of complex …
to determine the enthalpy change. While biosensors can quantitate the amount of complex …
[HTML][HTML] Real-time and label-free analysis of binding thermodynamics of carbohydrate-protein interactions on unfixed cancer cell surfaces using a QCM biosensor
X Li, S Song, Q Shuai, Y Pei, T Aastrup, Y Pei, Z Pei - Scientific reports, 2015 - nature.com
… surface carbohydrates was used as a model system for the thermodynamic analysis of
biomolecule interaction occurring on cell surface by QCM biosensor. The affinity constant (K D ) of …
biomolecule interaction occurring on cell surface by QCM biosensor. The affinity constant (K D ) of …
A thermodynamic characterization of the binding of thrombin inhibitors to human thrombin, combining biosensor technology, stopped-flow spectrophotometry, and …
J Deinum, L Gustavsson, E Gyzander… - Analytical …, 2002 - Elsevier
… of immobilized thrombin were used in the thermodynamic analyses of the highaffinity binders.
Surfaces with more than 4 kRU were used for KD analysis after further stabilization by an …
Surfaces with more than 4 kRU were used for KD analysis after further stabilization by an …
Biphasic thermodynamic characterization of interactions by quantitative affinity chromatography and biosensor technology
DJ Winzor - Journal of Chromatography A, 1998 - Elsevier
… by kinetic analysis of biosensor traces. Because … thermodynamic analysis (A+X⇄AX), the
parameters thus determined are necessarily the rate constants pertaining to the thermodynamic …
parameters thus determined are necessarily the rate constants pertaining to the thermodynamic …
Thermodynamic benchmark study using Biacore technology
I Navratilova, GA Papalia, RL Rich, D Bedinger… - Analytical …, 2007 - Elsevier
… that the affinities and thermodynamics determined using the biosensor matched the values
… consumption, thermodynamic analysis of interactions using Biacore biosensors can be done …
… consumption, thermodynamic analysis of interactions using Biacore biosensors can be done …
Direct comparison of binding equilibrium, thermodynamic, and rate constants determined by surface‐and solution‐based biophysical methods
YSN Day, CL Baird, RL Rich, DG Myszka - Protein Science, 2002 - Wiley Online Library
… resonance biosensor experiments are performed with care, the equilibrium, thermodynamic,
and … These results validate the use of biosensor technology to collect reliable data on small …
and … These results validate the use of biosensor technology to collect reliable data on small …
Thermodynamic analysis of the interaction between cationic porphyrins and human serum albumin by an optical biosensor
Q Yi‐Min, P Ni‐Na, J Yong‐Xing… - Chinese Journal of …, 2005 - Wiley Online Library
… of material required for typical analyses (generally requiring about 1 µg … the technology to
kinetic and thermodynamic analysis of … HSA using an optical biosensor with those obtained by …
kinetic and thermodynamic analysis of … HSA using an optical biosensor with those obtained by …
相关搜索
- biosensor technology thermodynamic characterization
- biosensor technology protein interactions
- biosensor technology quantitative affinity chromatography
- biosensor technology kinetic behavior
- biosensor measurements thermodynamic analysis
- optical biosensor thermodynamic analysis
- biosensor technology recombinant biomolecules
- biosensor technology evaluation of binding constants
- biosensor technology theoretical analysis
- macromolecular interactions thermodynamic analysis
- target interactions biosensor analysis
- binding thermodynamics qcm biosensor
- real time analysis qcm biosensor
- comparative analyses biacore technology
- biosensor technology protein concentration determination
- biosensor technology transport limitation