High-resolution infrared thermography of esophageal temperature during radiofrequency ablation of atrial fibrillation
MG Daly, I Melton, G Roper, G Lim… - Circulation: Arrhythmia …, 2018 - Am Heart Assoc
… using discrete sensor temperature probes have attempted to … radiofrequency (RF) ablation
catheter and the infrared … Atrial Fibrillation Pilot) patient during RF ablation. Image depicts the …
catheter and the infrared … Atrial Fibrillation Pilot) patient during RF ablation. Image depicts the …
Infrared thermography and thermocouple mapping of radiofrequency renal ablation to assess treatment adequacy and ablation margins
K Ogan, WW Roberts, DM Wilhelm, L Bonnell, D Leiner… - Urology, 2003 - Elsevier
… and probe, set at 105C for 5-minute ablations. During RF treatment, a laparoscopic infrared
(IR) … The colors displayed on the IR image during RF ablation were set to correspond to the …
(IR) … The colors displayed on the IR image during RF ablation were set to correspond to the …
[HTML][HTML] Techniques for temperature monitoring of myocardial tissue undergoing radiofrequency ablation treatments: an overview
… Explorative trials were performed by means of five RF ablations showing that the proposed
… Also, infrared probes placed in the esophagus lumen are used solely to avoid unwanted …
… Also, infrared probes placed in the esophagus lumen are used solely to avoid unwanted …
Oesophageal Probe Evaluation in Radiofrequency Ablation of Atrial Fibrillation (OPERA): results from a prospective randomized trial
K Schoene, A Arya, F Grashoff, H Knopp, A Weber… - EP …, 2020 - academic.oup.com
… the study was to determine the incidence of oesophageal lesions after radiofrequency ablation
(RFA) of atrial fibrillation (AF) with or without the use of oesophageal temperature probes. …
(RFA) of atrial fibrillation (AF) with or without the use of oesophageal temperature probes. …
Near-infrared spectroscopy integrated catheter for characterization of myocardial tissues: preliminary demonstrations to radiofrequency ablation therapy for atrial …
RP Singh-Moon, CC Marboe… - Biomedical optics …, 2015 - opg.optica.org
Effects of radiofrequency ablation (RFA) treatment of atrial fibrillation can be limited by the …
In this report, we present a near-infrared spectroscopy (NIRS)-integrated catheter capable of …
In this report, we present a near-infrared spectroscopy (NIRS)-integrated catheter capable of …
A review of the general aspects of radiofrequency ablation
… for the treatment of malignant tumors, radiofrequency ablation (RFA) has rapidly evolved
into … Radiofrequency (RF) is an electromagnetic wave frequency between audio and infrared …
into … Radiofrequency (RF) is an electromagnetic wave frequency between audio and infrared …
Real-time spectroscopic assessment of thermal damage: implications for radiofrequency ablation
CD Anderson, WC Lin, CR Buttemere… - Journal of …, 2004 - Springer
… or Rd spectra from liver tissue during each ablation through a microinterrogation probe (MIP…
and liver metastases in the near infrared range. Lasers Surg Med 1998;23:194–203. 33. …
and liver metastases in the near infrared range. Lasers Surg Med 1998;23:194–203. 33. …
Radiofrequency ablation: mechanism of action and devices
K Hong, C Georgiades - Journal of Vascular and Interventional Radiology, 2010 - Elsevier
… early RF description, large numbers of liver RF ablations … , RF ablation will need to deliver
larger tumor ablation volumes in a timely manner. The options for percutaneous tumor ablation …
larger tumor ablation volumes in a timely manner. The options for percutaneous tumor ablation …
Radiofrequency tissue ablation inside of metal stent–a thermographic study
V Bernard, T Andrašina, V Mornstein, V Válek - Irbm, 2014 - Elsevier
… ; radiofrequency ablation due by … Infrared camera seems to be an appropriate instrument
for observing the distribution and changes in temperature during ex vivo radiofrequency ablation…
for observing the distribution and changes in temperature during ex vivo radiofrequency ablation…
Photoacoustic imaging in percutaneous radiofrequency ablation: device guidance and ablation visualization
KJ Francis, S Manohar - Physics in Medicine & Biology, 2019 - iopscience.iop.org
… Percutaneous radiofrequency ablation (RFA) is gaining importance as a locoregional treatment
… for ex vivo studies of radiofrequency ablation (RFA) procedure. A probe holding the fiber …
… for ex vivo studies of radiofrequency ablation (RFA) procedure. A probe holding the fiber …
相关搜索
- radiofrequency ablation infrared thermography
- radiofrequency ablation atrial fibrillation
- radiofrequency ablation temperature monitoring
- radiofrequency ablation lesions
- radiofrequency ablation of renal tumors
- hepatic radiofrequency ablation
- radiofrequency ablation real time
- radiofrequency ablation fiber probe
- radiofrequency ablation photoacoustic imaging
- radiofrequency ablation outcomes
- radiofrequency ablation of myocardial tissue
- radiofrequency ablation treatments
- radiofrequency ablation in biological tissues
- radiofrequency ablation in the left atrium
- simultaneous radiofrequency ablation
- radiofrequency ablation therapies