Accuracy of digital breast tomosynthesis for depicting breast cancer subgroups in a UK retrospective reading study (TOMMY Trial)

FJ Gilbert, L Tucker, MGC Gillan, P Willsher, J Cooke… - Radiology, 2015 - pubs.rsna.org
… is higher in women younger than 50 years and with dense breasts (3–6). The development
of digital breast tomosynthesis ( DBT ) and its clinical application has been summarized in a …

Digital breast tomosynthesis: a pilot observer study

WF Good, GS Abrams, VJ Catullo… - American Journal of …, 2008 - Am Roentgen Ray Soc
… three readers initially read the FFDM examinations, three readers began with the frames,
and three readers began with the digital breast tomosynthesis images. Each reader interpreted …

Breast cancer screening with tomosynthesis—initial experiences

A Tingberg, D Förnvik, S Mattsson… - Radiation protection …, 2011 - academic.oup.com
… The sensitivity and specificity of breast tomosynthesis (BT) will be compared with … Based
on the experiences so far, the reading time of BT is significantly longer than the reading time of …

Screening for dense breasts: digital breast tomosynthesis

SV Destounis, R Morgan… - American journal of …, 2015 - Am Roentgen Ray Soc
… studies report reading times that are doubled in comparison with 2D FFDM reading times.
Dang et al. [25] studied the effect of implementing screening tomosynthesis on reading times. …

Digital breast tomosynthesis: observer performance study

D Gur, GS Abrams, DM Chough… - American Journal of …, 2009 - Am Roentgen Ray Soc
… The reconstructed slices were the digital breast tomosynthesis images. In this study, readers
were asked to primarily detect and rate masses and microcalcification clusters using FFDM …

Impact of artificial intelligence decision support using deep learning on breast cancer screening interpretation with single-view wide-angle digital breast tomosynthesis

MC Pinto, A Rodriguez-Ruiz, K Pedersen, S Hofvind… - Radiology, 2021 - pubs.rsna.org
reading times between the first and second AI-aided readingreading time and the AUC for
both reading conditions. Here, when using AI support, five readers reduced their reading time

[HTML][HTML] … of one-view breast tomosynthesis as a stand-alone breast cancer screening modality: results from the Malmö Breast Tomosynthesis Screening Trial, a …

K Lång, I Andersson, A Rosso, A Tingberg… - European …, 2016 - Springer
… We estimate that the reading time for one-view DBT in … the reading time in our study, since
the reading and scoring procedures were specific to the trial and would not reflect the true time

Breast cancer screening with digital breast tomosynthesis

P Skaane - Digital Breast Tomosynthesis: A Practical Approach, 2016 - Springer
… It is obvious that the interpretation of tomosynthesis will be more time-consuming. The
increased reading time for radiologists might turn out to be one of the really great challenges for …

A review of breast tomosynthesis. Part I. The image acquisition process

I Sechopoulos - Medical physics, 2013 - Wiley Online Library
… These include: (i) faster reading time, to keep the total acquisition time of all projections
to a minimum, with (ii) minimal ghosting and lag, which has been shown to introduce image …

Artificial intelligence for reducing workload in breast cancer screening with digital breast tomosynthesis

Y Shoshan, R Bakalo, F Gilboa-Solomon, V Ratner… - Radiology, 2022 - pubs.rsna.org
… for breast cancer screening, digital breast tomosynthesis (DBT… interpretation time is almost
twice that required for reading … could help to save time in the assessment of breast screening …