Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients: results from the …

BL Wilkoff, BD Williamson, RS Stern, SL Moore… - Journal of the American …, 2008 - jacc.org
Objectives: Our purpose was to demonstrate that strategically chosen implantable
cardioverter-defibrillator (ICD) ventricular tachycardia (VT) or ventricular fibrillation (VF) …

Predicting appropriate shocks in patients with heart failure: patient level meta‐analysis from SCD‐HeFT and MADIT II

EP Zeitler, SM Al‐Khatib, DJ Friedman… - Journal of …, 2017 - Wiley Online Library
Background No precise tools exist to predict appropriate shocks in patients with a primary
prevention ICD. We sought to identify characteristics predictive of appropriate shocks in …

Defensive Implantable Cardioverter-Defibrillator Programming Is Safe and Reduces Inappropriate Therapy―Comparison of 3 Programming Strategies in 1,471 …

AL Burger, S Stojkovic, H Schmidinger, R Ristl… - Circulation …, 2018 - jstage.jst.go.jp
Background: Careful device programming is necessary to reduce inappropriate
antitachycardia pacing (ATP) and shock therapy in recipients of implantable cardioverter …

Mortality and appropriate and inappropriate therapy in patients with ischaemic heart disease and implanted cardioverter-defibrillators for primary prevention: data from …

P Weeke, JB Johansen, OD Jørgensen, JC Nielsen… - Europace, 2013 - academic.oup.com
Aims To evaluate the incidences of and risk factors predisposing to appropriate and
inappropriate shocks and mortality in a 'real-world'population of patients with ischaemic …

Safety and efficacy of high-rate cutoff and long detection interval ICD programming in secondary prevention patients

Y Hayashi, M Takagi, J Kakihara, S Sakamoto, A Doi… - Heart and vessels, 2017 - Springer
Several trials demonstrated that a long detection interval and a high-rate cutoff reduced
implantable cardioverter-defibrillator (ICD) therapy in primary prevention patients. However …

Efficacy of long detection interval implantable cardioverter-defibrillator settings in secondary prevention population: data from the Avoid Delivering Therapies for …

A Kloppe, A Proclemer, A Arenal, M Lunati… - Circulation, 2014 - Am Heart Assoc
Background—Three trials demonstrated recently that a long detection window reduces
implantable cardioverter-defibrillator (ICD) therapy in primary prevention patients. Avoid …

Preventive implantable cardioverter defibrillator therapy in contemporary clinical practice: need for more stringent selection criteria

JW Deckers, B Arshi, JC van den Berge… - ESC Heart …, 2021 - Wiley Online Library
While the efficacy of the intracardiac defibrillators (ICDs) for primary prevention is not
disputed, the relevant studies were carried out a long time ago. Most pertinent trials …

Reduction in inappropriate therapies through device programming in subcutaneous implantable defibrillator patients: data from clinical practice

R Rordorf, S Viani, M Biffi, P Pieragnoli, F Migliore… - Europace, 2023 - academic.oup.com
Aims In subcutaneous implantable cardioverter defibrillator (S-ICD) recipients, the
UNTOUCHED study demonstrated a very low inappropriate shock rate on programming a …

The design of the Understanding Outcomes with the S‐ICD in Primary Prevention Patients with Low EF Study (UNTOUCHED)

MR Gold, R Knops, MC Burke… - Pacing and Clinical …, 2017 - Wiley Online Library
Background The UNTOUCHED study will assess the safety and efficacy of the
subcutaneous implantable cardioverter defibrillator (S‐ICD) in the most common cohort of …

A comparison of empiric to physician-tailored programming of implantable cardioverter-defibrillators: results from the prospective randomized multicenter EMPIRIC …

BL Wilkoff, KT Ousdigian, LD Sterns, ZJ Wang… - Journal of the American …, 2006 - jacc.org
Objectives: The purpose of this randomized study was to determine whether a strategically
chosen standardized set of programmable settings is at least as effective as physician …