Antitachycardia pacing for rapid VT during ICD charging: a method to prevent ICD shocks

M Weber, M Block, D Bänsch… - Pacing and Clinical …, 2001 - Wiley Online Library
WEBER, M., et al.: Antitachycardia Pacing for Rapid VT During ICD Charging: A Method to
Prevent ICD Shocks. In patients with ICDs, rapid VTs are usually treated with shocks. It is …

Antitachycardia pacing for reduction of implantable cardioverter-defibrillator shocks

DJ Cantillon, BL Wilkoff - Heart Rhythm, 2015 - Elsevier
Antitachycardia pacing (ATP) strategies represent safe, effective, and painless therapy for
ventricular tachyarrhythmias, with a large body of clinical evidence supporting their routine …

Clinical predictors and efficacy of antitachycardia pacing in patients with implantable cardioverter defibrillators: the importance of the patient's sex

RW Peters, X Zhang, MR Gold - Pacing and Clinical …, 2001 - Wiley Online Library
PETERS, RW, et al.: Clinical Predictors and Efficacy of Antitachycardia Pacing in Patients
with Implantable Cardioverter Defibrillators: The Importance of the Patient's Sex. The ICD …

Safety and efficacy of programming a high number of antitachycardia pacing attempts for fast ventricular tachycardia: a prospective study

RP Martins, H Blangy, L Muresan, L Freysz… - Europace, 2012 - academic.oup.com
Aims Little is known about the optimal number of antitachycardia pacing (ATP) attempts to
programme in the fast ventricular tachycardia (FVT) zone. We sought to analyse the long …

Automatic Implantable Cardioverter/Defibrillator (AICD) and Antitachycardia Pacemaker (Tachylog): Combined use in Ventricular Tachyarrhythmias: Defibrillateur …

B Lüderitz, U Gerckens, M Manz - Pacing and Clinical …, 1986 - Wiley Online Library
Antitachycardia pacing in ventricular tachyarrhythmias (VT) is associated with potential
acceleration of VT: frequency of VT and discomfort of the patient (pt) can limit treatment with …

Initial clinical experience with a new automated antitachycardia pacing algorithm: feasibility and safety in an ambulatory patient cohort

R Yee, JD Fisher, U Birgersdotter-Green… - Circulation …, 2017 - Am Heart Assoc
Background: Antitachycardia pacing (ATP) in implantable cardioverter-defibrillators (ICD)
decreases patient shock burden but has recognized limitations. A new automated ATP …

[HTML][HTML] Antitachycardia pacing programming in implantable cardioverter defibrillator: a systematic review

E De Maria, D Giacopelli, A Borghi… - World journal of …, 2017 - ncbi.nlm.nih.gov
Implantable cardioverter defibrillator (ICD) programming involves several parameters. In
recent years antitachycardia pacing (ATP) has gained an increasing importance in the …

Antitachycardia pacing: which patients and which methods?

M Rosenqvist - The American journal of cardiology, 1996 - Elsevier
This article is a review on the value of antitachycardia pacing in patients with implantable
cardiac-defibrillators (ICD). Antitachycardia pacing is highly effective in terminating …

[HTML][HTML] Reassessing the role of antitachycardia pacing in fast ventricular arrhythmias in primary prevention implantable cardioverter-defibrillator recipients: results …

C Schuger, JP Daubert, W Zareba, S Rosero, P Yong… - Heart Rhythm, 2021 - Elsevier
Background In Multicenter Automatic Defibrillator Implantation Trial–Reduce Inappropriate
Therapy (MADIT-RIT), high-rate cutoff (arm B) and delayed therapy (arm C) reduced the risk …

Basal exit site of clinical ventricular tachycardia is an independent predictor of antitachycardia pacing failure in implantable cardioverter‐defibrillators recipients

S Boule, F Brigadeau, C Marquie… - Pacing and clinical …, 2012 - Wiley Online Library
Background: Little is known about predictors of antitachycardia pacing (ATP) failure in
implantable cardioverter defibrillator (ICD) recipients. Distance between the stimulation site …