Endotracheal tube cuff pressure monitoring in peripheral hospitals

R Goyal, G Kumar, MR Waghray - Medical Journal Armed Forces India, 2006 - Elsevier
Background An improvised monitor was designed in a peripheral hospital to measure the
tracheal tube cuff pressures in patients intubated under anaesthesia. The aim of the study …

Measurement of endotracheal tube cuff pressure in ICU patients

JP Ranaweera - Sri Lankan Journal of Anaesthesiology, 2013 - slja.sljol.info
This audit was conducted in a University Hospital in United Kingdom to determine whether
tracheal tube cuffs were correctly inflated and to assess whether the cuff pressure was …

Measurement of endotracheal tube cuff pressure: Instrumental versus conventional method

MU Khan, R Khokar, S Qureshi… - Saudi journal of …, 2016 - journals.lww.com
Objective: To evaluate the conventional practice of endotracheal tube (ETT) cuff inflation and
pressure measurement as compared to the instrumental method. Study Design: Prospective …

[HTML][HTML] Comparison of tracheal tube cuff pressure with two techniques: fixed volume versus pilot balloon palpation

F Rahmani, H Soleimanpour, A Zeynali… - … of cardiovascular and …, 2017 - ncbi.nlm.nih.gov
Introduction: Filling tracheal tube cuff (TTC) after intubation is necessary to provide a safe
airway in intubated patients. On the other hand, excessive increase or decrease in the …

Anesthesia apparatus: Cuff Mate-2, endotracheal cuff inflator and pressure monitor.

I Swaiss, I Badran - Middle East Journal of Anaesthesiology, 2003 - europepmc.org
Objective A digital endotracheal cuff inflator and pressure monitor were tested under clinical
conditions on 150 patients in the intensive care. Methods Patients were either intubated with …

[PDF][PDF] Cuff pressure manometer-a luxury or necessity

S Balakrishnan, KK Jacob - Indian J Clin Anaesth, 2016 - academia.edu
Background: It is recommended to maintain endotracheal tube cuff pressure within a range
of 20 to 30 cm H2O to prevent complications. Objective: To assess the ability of experienced …

[HTML][HTML] Comparison of tracheal tube cuff pressure with two technique: fixed volume and minimal leak test techniques

S Sanaie, F Rahmani, S Chokhachian… - … of Cardiovascular and …, 2019 - ncbi.nlm.nih.gov
Introduction: There is a correlation between endotracheal cuff pressure and airway
complication; therefore, cuff pressure measurement is of an essential importance. The gold …

[HTML][HTML] Improvised technique for measuring tracheal tube cuff pressure

RA Flores-Franco - World Journal of Anesthesiology, 2016 - wjgnet.com
We agree with the editorial published by Feng et al concerning the insufficient routine
monitoring of tracheal tube cuff pressure (TTCP) by anesthesiologists, and propose an …

Educational Intervention Can Improve the Pilot Balloon Palpation Method of Tracheal Tube Cuff Pressure Monitoring: An Experimental Study

ADG Nwosu, EN Ossai, C Ejezie… - Journal of West African …, 2025 - journals.lww.com
Background: Considerable morbidity is attributable to inappropriate tracheal cuff pressure.
An earlier study undertaken in our hospital revealed that a normal cuff pressure of 20–30 cm …

Comparison of endotracheal tube cuff pressure values before and after training seminar

ATD Özcan, C Döğer, A But, I Kutlu… - Journal of Clinical …, 2018 - Springer
It is recommended that endotracheal cuff (ETTc) pressure be between 20 and 30 cm H 2 O.
In this present study, we intend to observe average cuff pressure values in our clinic and the …