[PDF][PDF] Insertion and removal eff ects of tooth supported overdentures on retention strength and fatigue resistance of attachment systems: An in vivo study

SJ Abichandani, N Abichandani - International Dental & Medical …, 2016 - researchgate.net
Background: Semi-precision attachments require repeated replacements and servicing in
use, so it is important to understand the time frame of this wear and its possible replacement …

[PDF][PDF] Effect of insertion and removal of tooth supported overdentures on retention strength and fatigue resistance of two commercially available attachment systems

SS Guttal, RK Nadiger… - Int J Prosthodont Restor …, 2012 - researchgate.net
Purpose: The main problem with semiprecision attachment retained prosthesis is that they
need frequent servicing in terms of replacing the female component. There is a need for a …

[HTML][HTML] In vitro retention capacity of two overdenture attachment systems: Locator® and Equator®

N Mínguez-Tomás… - Journal of clinical and …, 2018 - ncbi.nlm.nih.gov
Background It is necessary to know the in vitro behavior of different attachment systems to
be used clinically. The evolution of retention capacity over 10 years (14,600 insertion/de …

Comparative study of four retentive anchor systems for implant supported overdentures–retention force changes

S Bayer, D Steinheuser, M Grüner, L Keilig… - …, 2009 - Wiley Online Library
Objectives: Wear of attachments leads to a loss of retention and potentially reduces the
function of complete dentures. This study evaluated the retention force changes of different …

The service life of implant-retained overdenture attachment systems

MN Pigozzo, MF Mesquita, GEP Henriques… - The Journal of prosthetic …, 2009 - Elsevier
STATEMENT OF PROBLEM: Implant-retained overdentures are a treatment option for
patients who are not satisfied with conventional complete dentures. Although implant …

Effect of Cyclic Dislodging on the Retention of Two Attachment Systems for Implant-supported Overdentures: An In Vitro Study.

H Tohme, J Makzoume, P Boulos… - The Journal of …, 2018 - europepmc.org
Purpose The aim of this study was to compare and evaluate the retention of two new
attachment systems used for implant-supported overdentures subjected to insertion-removal …

An in vitro comparative study to evaluate the retention of different attachment systems used in implant-retained overdentures

T Shastry, NM Anupama, S Shetty… - The Journal of Indian …, 2016 - journals.lww.com
Aim: The aim of this in vitro study was to compare the change in the retentive force and
removal torque of three attachment systems during simulation of insertion-removal cycles …

Evaluation of retention forces and resistance to fatigue of attachment systems for overdentures: plastic and metal components

LC da Fontoura Frasca, PRC Mattia, DM Botega… - Implant …, 2014 - journals.lww.com
Purpose: To compare retention forces of 3 overdenture attachment systems with metal and
plastic components. Materials and Methods: Four samples of each system evaluated (Ball …

Effect of different retentive systems in the retention of implant-retained overdenture

LMP Sousa - 2023 - estudogeral.uc.pt
Introduction: In an attempt to promote the reestablishment of the quality of life of edentulous
patients, several therapeutic options arise, such as implant-retained overdentures, which …

The in vitro effect of different implant angulations and cyclic dislodgement on the retentive properties of an overdenture attachment system

SA Al-Ghafli, KX Michalakis, H Hirayama… - Journal of Prosthetic …, 2009 - thejpd.org
Purpose. The purpose of this in vitro study was to investigate the effect of cyclic
dislodgement on the retention of an overdenture attachment system when 2 implants were …