Comparison of endotracheal tube cuff pressure values before and after training seminar

ATD Özcan, C Döğer, A But, I Kutlu… - Journal of Clinical …, 2018 - Springer
It is recommended that endotracheal cuff (ETTc) pressure be between 20 and 30 cm H 2 O.
In this present study, we intend to observe average cuff pressure values in our clinic and the …

Measurement of endotracheal tube cuff pressure: Instrumental versus conventional method

MU Khan, R Khokar, S Qureshi… - Saudi journal of …, 2016 - journals.lww.com
Objective: To evaluate the conventional practice of endotracheal tube (ETT) cuff inflation and
pressure measurement as compared to the instrumental method. Study Design: Prospective …

Assessment of endotracheal cuff pressure by continuous monitoring: a pilot study

ML Sole, DA Penoyer, XG Su, E Jimenez… - American Journal of …, 2009 - AACN
Background Endotracheal tube cuff pressure must be maintained within a narrow
therapeutic range to prevent complications. Cuff pressure is measured and adjusted …

Endotracheal tube cuff pressure monitoring in intensive care units

F Zand, AA NEKOUEIAN, M ROUHANI - 2008 - sid.ir
Background: Improper inflation of endotracheal tube cuff is associated with various
complications. Recently, there has been high referral of patients with post-intubation …

[PDF][PDF] A comparison of endotracheal tube cuff pressures using estimation techniques and direct intracuff measurement

SL Stewart, JA Seacrest, BR Norwood, R Zachary - AANA journal, 2003 - nghiemviet.vn
Cuffed endotracheal tubes are one aspect of airway management designed to ensure
safety, yet patients can be at risk for injury from underinflated and overinflated endotracheal …

[PDF][PDF] Cuff pressure manometer-a luxury or necessity

S Balakrishnan, KK Jacob - Indian J Clin Anaesth, 2016 - academia.edu
Background: It is recommended to maintain endotracheal tube cuff pressure within a range
of 20 to 30 cm H2O to prevent complications. Objective: To assess the ability of experienced …

A mobile terminal application program was used for endotracheal tube cuff pressure measurement

WZ Wang, YY Zhou, ZJ Wang, ML Zhu, XY Yao… - Journal of Clinical …, 2021 - Springer
We studied the application of a mobile terminal application program in endotracheal tube
(ETT) cuff pressure measurement to improve the implementation rate of scientific ETT cuff …

Reliability of cuff pressure gauges

J Raft, AS Lamotte, B Maury, I Clerc-Urmès… - Journal of Clinical …, 2019 - Springer
Cuff pressure gauges are the only recommended instrument to perform controls on
endotracheal tube cuff pressure during anesthesia. No calibration is mandatory for these …

Endotracheal tube cuff pressure in three hospitals, and the volume required to produce an appropriate cuff pressure

P Sengupta, DI Sessler, P Maglinger, S Wells… - BMC …, 2004 - Springer
Background Cuff pressure in endotracheal (ET) tubes should be in the range of 20–30 cm H
2 O. We tested the hypothesis that the tube cuff is inadequately inflated when manometers …

Endotracheal tube cuff pressure monitoring in peripheral hospitals

R Goyal, G Kumar, MR Waghray - Medical Journal Armed Forces India, 2006 - Elsevier
Background An improvised monitor was designed in a peripheral hospital to measure the
tracheal tube cuff pressures in patients intubated under anaesthesia. The aim of the study …