Safety profile of minimally invasive glaucoma surgery

K Vinod, SJ Gedde - Current opinion in ophthalmology, 2021 - journals.lww.com
Trabecular meshwork/Schlemm's canal-based procedures are generally among the safest
MIGS, with mostly self-limited and nonvision-threatening complications. Subconjunctival gel …

Three‐year effectiveness and safety of the XEN gel stent as a solo procedure or in combination with phacoemulsification in open‐angle glaucoma: a multicentre study

H Reitsamer, V Vera, S Ruben, L Au… - Acta …, 2022 - Wiley Online Library
Purpose To assess the 3‐year effectiveness and safety of the XEN gel stent implanted ab
interno in open‐angle glaucoma (OAG). Methods This study was a multicentre, retrospective …

Efficacy of needling revision after XEN gel stent implantation: a prospective study

N Midha, K Gillmann, A Chaudhary… - Journal of …, 2020 - journals.lww.com
Methods: This was a prospective, interventional study, conducted at a single tertiary
glaucoma center. Fifty-one eyes of 51 patients with raised IOP associated with either a …

Two‐year outcomes of minimally invasive XEN Gel Stent implantation in primary open‐angle and pseudoexfoliation glaucoma

T Rauchegger, R Angermann, P Willeit… - Acta …, 2021 - Wiley Online Library
Purpose The aim of this study was to evaluate the efficacy of XEN® Gel Stent implantation in
the treatment of primary open‐angle glaucoma (POAG) and pseudoexfoliation glaucoma …

[HTML][HTML] Late-onset Endophthalmitis after XEN45® Implantation: A retrospective case series and literature review

RBS de Las Matas, L Such-Irusta… - Journal of Current …, 2021 - ncbi.nlm.nih.gov
Background Long-term safety profile and efficacy in relation to the so-called microinvasive
glaucoma surgery (MIGS) techniques are still under evaluation. The XEN45® gel stent …

Four-Year Outcome of XEN 45 gel stent implantation in a Swedish population

T Busch, D Skiljic, T Rudolph, A Bergström… - Clinical …, 2023 - Taylor & Francis
Purpose To report the long-time success rate of XEN 45 gel stent implantation in a
Scandinavian population. Patients and Methods This was a retrospective single-center …

Nanofiber‐based glaucoma drainage implant improves surgical outcomes by modulating fibroblast behavior

A Josyula, A Mozzer, J Szeto, Y Ha… - Bioengineering & …, 2023 - Wiley Online Library
Biomaterials are implanted in millions of individuals worldwide each year. Both naturally
derived and synthetic biomaterials induce a foreign body reaction that often culminates in …

Surgical approaches for implanting XEN gel stent without conjunctival dissection

V Vera, S Gagne, JS Myers, IIK Ahmed - Clinical Ophthalmology, 2020 - Taylor & Francis
Abstract The XEN Gel Stent (Allergan Inc., an Abbvie company) is an implant that lowers
intraocular pressure by creating a filtration pathway from the anterior chamber to the …

Comparison of clinical outcomes following gel stent implantation via ab-externo and ab-interno approaches in patients with refractory glaucoma

MJ Gallardo, LR Vincent, M Porter - Clinical Ophthalmology, 2022 - Taylor & Francis
Purpose To compare clinical outcomes following gel stent implantation via ab externo and
ab interno approaches in patients with refractory glaucoma. Patients and Methods This …

Learning curve and one-year outcome of XEN 45 gel stent implantation in a Swedish population

T Busch, D Skiljic, T Rudolph, A Bergström… - Clinical …, 2020 - Taylor & Francis
Purpose Evaluation of 1-year-outcome of XEN 45 gel stent surgery in a Swedish cohort with
regard to clinical success, complications, and learning curve. Patients and Methods This …