Complications and post-operative interventions in XEN45 gel stent implantation in the treatment of open angle glaucoma—a systematic review and meta-analysis
BK Betzler, SY Lim, BA Lim, VCH Yip, BCH Ang - Eye, 2023 - nature.com
Abstract Background The XEN45 Gel Stent is a subconjunctival filtering device that has
demonstrated promising efficacy. This meta-analysis quantitatively evaluates reported …
demonstrated promising efficacy. This meta-analysis quantitatively evaluates reported …
Standalone XEN45 Gel Stent implantation in the treatment of open-angle glaucoma: A systematic review and meta-analysis
Abstract The XEN45 Gel Stent (Allergan Inc., Irvine, CA) allows the drainage of aqueous into
the sub-conjunctival space, through a minimally-invasive approach. This systematic review …
the sub-conjunctival space, through a minimally-invasive approach. This systematic review …
Two-year outcomes of Xen 45 gel stent implantation in patients with open-angle glaucoma: real-world data from the Fight Glaucoma Blindness registry
L Arnould, E Balsat, Y Hashimoto, A White… - British Journal of …, 2024 - bjo.bmj.com
Objective To evaluate efficacy and safety outcomes of the Xen 45 gel stent implant over 24
months of follow-up. Methods A retrospective analysis of prospectively collected data from …
months of follow-up. Methods A retrospective analysis of prospectively collected data from …
Clinical outcomes of ab interno placement versus ab externo placement of XEN45 gel stents
RC Ruda, L Yuan, GM Lai, S Raiciulescu… - Ophthalmology …, 2023 - Elsevier
Purpose To compare the effectiveness of ab interno versus ab externo placement of XEN45
gel stents in patients with open-angle glaucoma. Design Single-center, noncontrolled …
gel stents in patients with open-angle glaucoma. Design Single-center, noncontrolled …
XEN 45 GEL Stent implantation in open angle glaucoma: 5-year results of a prospective study
J Torbey, A Paillard, HL Rao, K Gillman… - Journal of …, 2023 - journals.lww.com
Purpose: To evaluate 5-year outcomes of XEN 45 gel stent implantation (XEN) in patients
with open angle glaucoma. Methods: This is a prospective, single-center, interventional …
with open angle glaucoma. Methods: This is a prospective, single-center, interventional …
Standalone Xen45 Gel Stent implantation versus combined Xen45-phacoemulsification in the treatment of open angle glaucoma—A systematic review and meta …
Abstract Purpose The XEN45 Gel Stent is currently the only FDA-approved sub-conjunctival
minimally invasive glaucoma surgery (MIGS) procedure. It has been used worldwide either …
minimally invasive glaucoma surgery (MIGS) procedure. It has been used worldwide either …
[HTML][HTML] Comparison of clinical outcomes with open versus closed conjunctiva implantation of the XEN45 gel stent
A Do, E McGlumphy, A Shukla, S Dangda… - Ophthalmology …, 2021 - Elsevier
Purpose To describe the efficacy and safety of open versus closed conjunctival implantation
of the XEN45 Gel Stent (Allergan Inc). Design Retrospective, multicenter study. Participants …
of the XEN45 Gel Stent (Allergan Inc). Design Retrospective, multicenter study. Participants …
Three-year clinical outcome of XEN45 Gel Stent implantation versus trabeculectomy in patients with open angle glaucoma
T Rauchegger, SM Krause, Y Nowosielski, AL Huber… - Eye, 2024 - nature.com
Objective To reliably compare the three-year clinical outcome and safety of XEN45 Gel Stent
implantation (XEN) vs. trabeculectomy (TRAB) in patients with glaucoma. Subject/methods …
implantation (XEN) vs. trabeculectomy (TRAB) in patients with glaucoma. Subject/methods …
Two-year outcomes of XEN gel stent surgery in patients with open-angle glaucoma
Purpose To evaluate the 2-year treatment outcomes of the XEN gel stent (Allergan, Inc,
Irvine, CA) in glaucoma patients. Design Prospective, single-center interventional study …
Irvine, CA) in glaucoma patients. Design Prospective, single-center interventional study …
Efficacy and safety data for the Ab interno XEN45 gel stent implant at 3 Years: A retrospective analysis
IE Gabbay, M Goldberg, F Allen, Z Lin… - European Journal …, 2022 - journals.sagepub.com
Purpose: To report efficacy and safety measures of the XEN45 gel stent at 36 months in the
UK National Health Service setting. Methods: Retrospective non-comparative audit of the …
UK National Health Service setting. Methods: Retrospective non-comparative audit of the …