Fast label-free detection of C-reactive protein using broad-band Mach-Zehnder interferometers integrated on silicon chips
A Psarouli, A Botsialas, A Salapatas, G Stefanitsis… - Talanta, 2017 - Elsevier
An immunosensor for fast and accurate determination of C-reactive protein (CRP) in human
serum samples based on an array of all-silicon broad-band Mach-Zehnder interferometers …
serum samples based on an array of all-silicon broad-band Mach-Zehnder interferometers …
Impedimetric, diamond-based immmunosensor for the detection of C-reactive protein
V Vermeeren, L Grieten, NV Bon, N Bijnens… - Sensors and Actuators B …, 2011 - Elsevier
The high prevalence of cardiovascular diseases (CVD) demands a reliable and sensitive
risk assessment technique. In order to develop a fast and label-free immunosensor for C …
risk assessment technique. In order to develop a fast and label-free immunosensor for C …
[PDF][PDF] The Mach-Zehnder interferometer based on silicon oxides for label free detection of C-reactive protein (CRP)
The C-reactive protein (CRP) is a very important inflammation biomarker and a major
predictor of cardiovascular disease (CVD) in human. We demonstrated here on a new …
predictor of cardiovascular disease (CVD) in human. We demonstrated here on a new …
A new device based on interferometric optical detection method for label-free screening of C-reactive protein
In previous work, the performance of a compact and cost-effective point-of-care (PoC) device
based on the increase relative optical power (IROP) methodology is reported and it is …
based on the increase relative optical power (IROP) methodology is reported and it is …
Rapid C-reactive protein determination in whole blood with a White Light Reflectance Spectroscopy label-free immunosensor for Point-of-Care applications
G Koukouvinos, D Goustouridis, K Misiakos… - Sensors and Actuators B …, 2018 - Elsevier
The fast and accurate determination of C-reactive protein (CRP) in human whole blood
samples employing a white light reflectance spectroscopy sensing platform is demonstrated …
samples employing a white light reflectance spectroscopy sensing platform is demonstrated …
Ultrahigh-frequency, wireless MEMS QCM biosensor for direct, label-free detection of biomarkers in a large amount of contaminants
K Noi, A Iwata, F Kato, H Ogi - Analytical chemistry, 2019 - ACS Publications
Label-free biosensors, including conventional quartz-crystal-microbalance (QCM)
biosensors, are seriously affected by nonspecific adsorption of contaminants involved in …
biosensors, are seriously affected by nonspecific adsorption of contaminants involved in …
Two immunoassay formats for fully automated CRP detection in human serum
C Albrecht, N Kaeppel, G Gauglitz - Analytical and bioanalytical chemistry, 2008 - Springer
Immunoassays are a proven approach towards fast, sensitive, cost-effective and easy-to-use
analytical systems which are able to measure a variety of interesting analytes, especially in …
analytical systems which are able to measure a variety of interesting analytes, especially in …
Direct immunosensing by spectral correlation interferometry: assay characteristics versus antibody immobilization chemistry
A 3-channel biosensor based on spectral correlation interferometry (SCI) has been adapted
for direct optical detection of antigens by measuring changes in thickness of a biolayer on …
for direct optical detection of antigens by measuring changes in thickness of a biolayer on …
Imaging and chemical surface analysis of biomolecular functionalization of monolithically integrated on silicon Mach-Zehnder interferometric immunosensors
K Gajos, M Angelopoulou, P Petrou, K Awsiuk… - Applied Surface …, 2016 - Elsevier
Time-of-flight secondary ion mass spectrometry (imaging, micro-analysis) has been
employed to evaluate biofunctionalization of the sensing arm areas of Mach-Zehnder …
employed to evaluate biofunctionalization of the sensing arm areas of Mach-Zehnder …
Broad-band mach-zehnder interferometry as a detection principle for label-free biochemical sensing
M Kitsara, I Raptis, K Misiakos… - SENSORS, 2008 …, 2008 - ieeexplore.ieee.org
In this work the Broad-Band Mach-Zehnder Interferometry (BB-MZI) is presented as an
alternative operation principle for optical biochemical sensors that will allow for ultra …
alternative operation principle for optical biochemical sensors that will allow for ultra …