Which priming fluids?

MA Tobias, JM Fryer - Towards Safer Cardiac Surgery: Based upon the …, 1981 - Springer
It is 16 years since the South Central Association of Blood Banks met in Oklahoma City
under the chairmanship of Dr Zuhdi and discussed which priming fluids were most suitable …

Effects of hypertonic saline (7.5%)/dextran 70 on human red cell typing, lysis, and metabolism in vitro

GL Moore, JJ Summary, MA Dubick, ME Ledford… - Vox sanguinis, 1990 - karger.com
Abstract The introduction of a 7.5% hypertonic saline/6% dextran 70 (HSD) solution into
clinical trials for the treatment of hypovolemic states, and the past concerns regarding the …

Haemoglobin solution as an oxygen-carrying resuscitation fluid in haemorrhagic shock

W Odling-Smee, C McLarnon - Irish journal of medical science, 1984 - Springer
A SOLUTION of pyridoxalated haemoglobin has been prepared and tested in an animal
shock model by comparing its efficiency in resuscitating an animal from hypovolaemic shock …

A comparison of the effects of salbutamol, etilefrine and dextran during hypotension and low cardiac output states in rabbit

SA Adigun, PH Fentem - Clinical and experimental …, 1984 - Wiley Online Library
The effects of salbutamol (25 and 50 μg/kg), etilefrine (50 and 200 μg/kg) and dextran (8
ml/kg) on cardiovascular function have been studied in the rabbit. 2. The three drugs raised …

Increased erythrocyte sedimentation rate following anti-thrombotic treatment with dextrans

JS Rø, T Kluge - … Journal of Thoracic and Cardiovascular Surgery, 1971 - Taylor & Francis
The influence of clinical dextran preparations was studied in two groups of patients
subjected to vascular surgery. In those receiving dextran 70 the erythrocyte sedimentation …

Anemia and hyperbaric oxygenation in dogs subjected to coronary artery ligations

E Ruiz, JJ Haglin, CR Hitchcock - Journal of Surgical Research, 1972 - Elsevier
Coronary artery ligations were performed in anesthetized, closed-chested dogs using
snares. Cardiac output was measured with an electromagnetic flowmeter. Hyperbaric …

Effects of dextrans on the plasma protein changes during the postoperative period

S Skrede, JS Rø, O Mjølnerød - Clinica Chimica Acta, 1973 - Elsevier
The patterns of various plasma proteins after operation were studied in control patients and
in patients given either Macrodex® or Rheomacrodex® for 5 consecutive days. The protein …

Blood and blood substitutes for treating hemorragic shock.

EC Buchanan - American Journal of Hospital Pharmacy, 1977 - europepmc.org
Blood substitute products for the treatment of hemorrhagic shock are discussed with regard
to their composition, physical and therapeutic characteristics, adverse effects, cost, and …

Red cell aggregation induced by a high molecular weight gelatin plasma substitute

PM Scholz, J Engeset, NA Matheson… - European Surgical …, 1971 - karger.com
In the course of clinical investigation of a new higher molecular weight plasma substitute
made of gelatin (MW 60,000), severe side reactions were observed in 2 patients. As the …

Haemostatic parameters and erythrocyte sedimentation rate in dextran-warfarin treated vascular surgical patients

JS Rø, TH Kluge, S Taksdal… - Scandinavian Journal of …, 1974 - Taylor & Francis
Haematological tests and parameters of coagulation and fibrinolysis were studied in 13
patients given postoperative thrombosis prophylaxis with dextran 70 (Macrodex) or dextran …