Targeted superparamagnetic iron oxide nanoparticles for early detection of cancer: Possibilities and challenges

Z Bakhtiary, AA Saei, MJ Hajipour, M Raoufi… - … , Biology and Medicine, 2016 - Elsevier
Nanomedicine, the integration of nanotechnological tools in medicine demonstrated
promising potential to revolutionize the diagnosis and treatment of various human health …

Short-T2 MRI: Principles and recent advances

M Weiger, KP Pruessmann - Progress in nuclear magnetic resonance …, 2019 - Elsevier
Among current modalities of biomedical and diagnostic imaging, MRI stands out by virtue of
its versatile contrast obtained without ionizing radiation. However, in various cases, eg …

Optimized 3D ultrashort echo time pulmonary MRI

KM Johnson, SB Fain, ML Schiebler… - Magnetic resonance in …, 2013 - Wiley Online Library
Purpose To optimize 3D radial ultrashort echo time MRI for high resolution whole‐lung
imaging. Methods 3D radial ultrashort echo time was implemented on a 3T scanner to …

MRI with zero echo time: hard versus sweep pulse excitation

M Weiger, KP Pruessmann… - Magnetic resonance in …, 2011 - Wiley Online Library
Zero echo time can be obtained in MRI by performing radiofrequency (RF) excitation as well
as acquisition in the presence of a constant gradient applied for purely frequency‐encoded …

Regional Ventilation Changes in Severe Asthma after Bronchial Thermoplasty with 3He MR Imaging and CT

RP Thomen, A Sheshadri, JD Quirk, J Kozlowski… - Radiology, 2015 - pubs.rsna.org
Purpose To quantify regional lung ventilation in healthy volunteers and patients with severe
asthma (both before and after thermoplasty) by using a combination of helium 3 (3He) …

High‐resolution ZTE imaging of human teeth

M Weiger, KP Pruessmann, AK Bracher… - NMR in …, 2012 - Wiley Online Library
MRI with zero echo time (ZTE) is achieved by 3D radial centre‐out encoding and hard‐pulse
RF excitation while the projection gradient is already on. Targeting short‐T2 samples, the …

Ultrashort echo time (UTE) MRI of the lung: assessment of tissue density in the lung parenchyma

O Togao, R Tsuji, Y Ohno, I Dimitrov… - Magnetic resonance …, 2010 - Wiley Online Library
Nonuniform disruption of lung architecture is usually assessed by CT, which carries potential
radiation risk. Here we report our use of a three‐dimensional ultrashort echo time MR …

Quantitative sodium imaging with a flexible twisted projection pulse sequence

A Lu, IC Atkinson, TC Claiborne… - … in Medicine: An …, 2010 - Wiley Online Library
The quantification of sodium MR images from an arbitrary intensity scale into a bioscale
fosters image interpretation in terms of the spatially resolved biochemical process of sodium …

Free-breathing, zero-TE MR lung imaging

F Gibiino, L Sacolick, A Menini, L Landini… - … Resonance Materials in …, 2015 - Springer
Object The investigation of three-dimensional radial, zero-echo time (TE) imaging for high-
resolution, free-breathing magnetic resonance (MR) lung imaging using prospective and …

Ultra‐short echo time (UTE) MR imaging of the lung: comparison between normal and emphysematous lungs in mutant mice

M Takahashi, O Togao, M Obara… - Journal of magnetic …, 2010 - Wiley Online Library
Purpose: To investigate the utility of ultra‐short echo time (UTE) sequence as pulmonary
MRI to detect non‐uniform disruption of lung architecture that is typical of emphysema …