[HTML][HTML] Biomechanical aspects of various attachments for implant overdentures: A review
B Mirchandani, T Zhou, A Heboyan, S Yodmongkol… - Polymers, 2021 - mdpi.com
There have been considerable recent technological developments for implant overdenture
attachments. This study presents an overview of the biomechanical and biomolecular …
attachments. This study presents an overview of the biomechanical and biomolecular …
[HTML][HTML] Evaluation of retention, wear, and maintenance of attachment systems for single-or two-implant-retained mandibular overdentures: a systematic review
R Wakam, A Benoit, KB Mawussi, C Gorin - Materials, 2022 - mdpi.com
Attachment systems (AS) enhance retention and stability by anchoring the overdentures to
implants. Since 2002, the McGill consensus statement recommends the 2-implant-retained …
implants. Since 2002, the McGill consensus statement recommends the 2-implant-retained …
Effects of in vitro cyclic dislodging on retentive force and removal torque of three overdenture attachment systems
M Kobayashi, M Srinivasan, P Ammann… - Clinical oral implants …, 2014 - Wiley Online Library
Background Mandibular two‐implant‐retained overdentures were suggested as first choice
of treatment for edentulous mandibles. However, wear of the attachments may reduce their …
of treatment for edentulous mandibles. However, wear of the attachments may reduce their …
Long-term retention behaviour of resin matrix attachment systems for overdentures
Objectives The purpose of this laboratory study was to evaluate the long-term retention
behaviour of two resin matrix attachment systems for overdentures and the influence of the …
behaviour of two resin matrix attachment systems for overdentures and the influence of the …
[PDF][PDF] Clinical outcomes of rigid and non-rigid telescopic double-crown-retained removable dental prostheses: An analytical review
SY Song, KH Kang, JY Lee, SW Shin… - The journal of …, 2020 - synapse.koreamed.org
PURPOSE The purpose of this study is to evaluate the effects of type of magnet attachment
and implant angulation in two implant overdenture models. MATERIALS AND METHODS …
and implant angulation in two implant overdenture models. MATERIALS AND METHODS …
[HTML][HTML] An in vitro comparative study to evaluate the retention of different attachment systems used in implant-retained overdentures
T Shastry, NM Anupama, S Shetty… - The Journal of Indian …, 2016 - journals.lww.com
Aim: The aim of this in vitro study was to compare the change in the retentive force and
removal torque of three attachment systems during simulation of insertion-removal cycles …
removal torque of three attachment systems during simulation of insertion-removal cycles …
[HTML][HTML] FEM Analysis of Dental Implant-Abutment Interface Overdenture Components and Parametric Evaluation of Equator® and Locator® Prosthodontics …
The objective of this investigation was to analyze the mechanical features of two different
prosthetic retention devices. By applying engineering tools like the finite element method …
prosthetic retention devices. By applying engineering tools like the finite element method …
Retention and wear of resin matrix attachments for implant overdentures
N Wichmann, M Kern, T Taylor, S Wille… - Journal of the mechanical …, 2020 - Elsevier
Objectives The aim of the present laboratory study was to investigate the retentive properties
and the wear of three different resin matrix attachments for implant overdentures as well as …
and the wear of three different resin matrix attachments for implant overdentures as well as …
The influence of interimplant divergence on the retention characteristics of locator attachments, a laboratory study
GJ Stephens, N di Vitale, E O'Sullivan… - Journal of …, 2014 - Wiley Online Library
Purpose The aim of the study was to assess the influence of interimplant divergence on
retention of two Locator attachments before and after in vitro simulation of 3 to 5 years of …
retention of two Locator attachments before and after in vitro simulation of 3 to 5 years of …
[HTML][HTML] Strains around distally inclined implants retaining mandibular overdentures with Locator attachments: an in vitro study
MA Elsyad, FA Setta… - The journal of advanced …, 2016 - synapse.koreamed.org
PURPOSE The aim of the present study was to evaluate, by means of strain gauge analysis,
the effect of different implant angulations on strains around two implants retaining …
the effect of different implant angulations on strains around two implants retaining …