The importance of electrode location in cochlear implantation

BP O'Connell, JB Hunter… - Laryngoscope …, 2016 - Wiley Online Library
Objectives As indications for cochlear implantation have expanded to include patients with
more residual hearing, increasing emphasis has been placed on minimally traumatic …

Potential insertion complications with cochlear implant electrodes

A Ishiyama, F Risi, P Boyd - Cochlear Implants International, 2020 - Taylor & Francis
Objectives: The aim of this discussion paper and literature review was to estimate the
incidence of a variety of complications associated with the surgical placement of cochlear …

Clinical investigation of the nucleus slim modiolar electrode

A Aschendorff, R Briggs, G Brademann… - Audiology and …, 2017 - karger.com
Aims: The Nucleus CI532 cochlear implant incorporates a new precurved electrode array, ie,
the Slim Modiolar electrode (SME), which is designed to bring electrode contacts close to …

Scalar localization by cone-beam computed tomography of cochlear implant carriers: a comparative study between straight and periomodiolar precurved electrode …

E Boyer, A Karkas, A Attye, V Lefournier… - Otology & …, 2015 - journals.lww.com
Scalar Localization by Cone-Beam Computed Tomography of Coch... : Otology &
Neurotology Scalar Localization by Cone-Beam Computed Tomography of Cochlear …

Flat-panel conebeam CT in the clinic: history and current state

R Fahrig, DA Jaffray, I Sechopoulos… - Journal of Medical …, 2021 - spiedigitallibrary.org
Research into conebeam CT concepts began as soon as the first clinical single-slice CT
scanner was conceived. Early implementations of conebeam CT in the 1980s focused on …

Assessment of cochlear trauma during cochlear implantation using electrocochleography and cone beam computed tomography

A Dalbert, A Huber, D Veraguth, C Roosli… - Otology & …, 2016 - journals.lww.com
Objective: To assess cochlear trauma during cochlear implantation by electrocochleography
(ECoG) and cone beam computed tomography (CBCT) and to correlate intraoperative …

Association between flat-panel computed tomographic imaging–guided place-pitch mapping and speech and pitch perception in Cochlear implant users

NT Jiam, M Gilbert, D Cooke… - … –Head & Neck …, 2019 - jamanetwork.com
Importance Cochlear implant users generally display poor pitch perception. Flat-panel
computed tomography (FPCT) has recently emerged as a modality capable of localizing …

Automatic electrode scalar location assessment after cochlear implantation using a novel imaging software

S Geiger, M Iso-Mustajärvi, T Nauwelaers, E Avci… - Scientific Reports, 2023 - nature.com
As of today, image-based assessment of cochlear implant electrode array location is not part
of the clinical routine. Low resolution and contrast of computer tomography (CT) imaging, as …

Initial surgical and clinical experience with the Nucleus CI532 slim modiolar electrode in the UK

M Gomez Serrano, S Patel, R Harris… - Cochlear Implants …, 2019 - Taylor & Francis
Objective The goal of this work is to describe the first experience in the UK with the slim pre-
curved perimodiolar electrode Nucleus CI532 in a continuous series of patients in terms of …

A new slim modiolar electrode array for cochlear implantation: a radiological and histological study

M Iso-Mustajärvi, H Matikka, F Risi, S Sipari… - Otology & …, 2017 - journals.lww.com
Background: Hearing and structure preservation is the goal of cochlear implantation for
advanced hearing outcomes. Currently, this is most consistently achieved with thin lateral …