Report of AAPM task group 235 radiochromic film dosimetry: an update to TG‐55

A Niroomand‐Rad, ST Chiu‐Tsao, MP Grams… - Medical …, 2020 - Wiley Online Library
The use of radiochromic film (RCF) dosimetry in radiation therapy is extensive due to its high
level of achievable accuracy for a wide range of dose values and its suitability under a …

Effects of heterogeneities in dose distributions under nonreference conditions: Monte Carlo simulation vs dose calculation algorithms

CQM Reis, P Nicolucci, SS Fortes, LP Silva - Medical Dosimetry, 2019 - Elsevier
The purpose of this study is to evaluate the performance of dose calculation algorithms used
in radiotherapy treatment planning systems (TPSs) in comparison with Monte Carlo (MC) …

[HTML][HTML] Dosimetric verification by using the ArcCHECK system and 3DVH software for various target sizes

JH Song, HJ Shin, CS Kay, SH Son - PLoS One, 2015 - journals.plos.org
Objective To investigate the usefulness of the 3DVH software with an ArcCHECK 3D diode
array detector in newly designed plans with various target sizes. Methods The isocenter …

[HTML][HTML] Investigation of tube voltage dependence on CT number and its effect on dose calculation algorithms using thorax phantom in Monaco treatment planning …

A Saini, VP Pandey, P Kumar, A Singh… - Journal of Medical …, 2021 - journals.lww.com
Materials and Methods: CIRS thorax phantom with different density material plugs was
scanned at varying tube voltages from CT scanner and HU values were measured in …

Accuracy of dose calculation algorithms for static and rotational IMRT of lung cancer: A phantom study

C Sini, S Broggi, C Fiorino, GM Cattaneo, R Calandrino - Physica Medica, 2015 - Elsevier
Purpose To evaluate the dosimetric accuracy of Pencil beam (PB), Anisotropic Analytical
Algorithm (AAA) and Collapsed Cone Convolution Superposition (CCCS) in thoracic …

[PDF][PDF] Octavius1500 电离室矩阵基于模体和CT 影像

郭逸潇, 李亚洲, 刘志强, 缪国英, 蔡宏懿 - 辐射研究与辐射工艺学报, 2021 - fs.sinap.ac.cn
摘要利用Octavius1500 电离室矩阵进行RapidArc 计划剂量验证, 探讨基于CT 影像重建3D
剂量的可行性和影响剂量重建精度的因素. 选取106 例不同解剖部位RapidArc 计划(31 例头颈 …

[HTML][HTML] Comparison of Monaco treatment planning system algorithms and Monte Carlo simulation for small fields in anthropomorphic RANDO phantom: The …

T Tugrul - Journal of Cancer Research and Therapeutics, 2021 - journals.lww.com
Background: In this study, the dose distributions obtained by the algorithms used in Monaco
treatment planning system (TPS) and Monte Carlo (MC) simulation were compared for small …

[PDF][PDF] Dosimetric comparison and plan evaluation of different dose computing algorithms for different radiotherapy techniques in head and neck tumors

B Pandu, R Elavarasan, V TR, S Jacob… - Iranian Journal of …, 2022 - researchgate.net
Results: In the IMRT plan, mean dose, Conformity Index (CI), D2%, D98%, and D50%
showed a significant difference in p-values (p< 0.05), but the critical structure did not have a …

Linking dose delivery accuracy and planning target margin in radiosurgery based on dose-volume histograms derived from measurement-guided dose reconstruction

MKH Chan, RWK Leung, VWY Lee… - Physics in Medicine …, 2019 - iopscience.iop.org
In radiosurgery (SRS), the geometric uncertainties of machine-related delivery including
image-guidance and hence the planning target volume (PTV) are often evaluated by the end …

Clinical Evaluation of X-Ray Voxel Monte Carlo Versus Pencil Beam–Based Dose Calculation in Stereotactic Body Radiotherapy of Lung Cancer Under Normal and …

V Landoni, GR Borzi, S Strolin… - … in Cancer Research …, 2015 - journals.sagepub.com
The purpose of this study is to evaluate the differences between dose distributions
calculated with the pencil beam (PB) and X-ray voxel Monte Carlo (MC) algorithms for …