Potentially toxic metallic wear nanoparticles and trace metal ions release from metal-on-metal orthopedic implants in the human biological specimens: An Overview of …

H Matusiewicz, M Richter - World Journal of Advanced Research and …, 2020 - wjarr.com
The use of metallic biomaterials in the medical implant devices has become increasingly
prevalent over the past few decades. Patients find themselves being exposed to metals in a …

The cobalt/chromium ratio provides similar diagnostic value to a low cobalt threshold in predicting adverse local tissue reactions in patients with metal-on-metal hip …

I Laaksonen, VP Galea, GS Donahue… - The Journal of …, 2018 - Elsevier
Background A higher cobalt/chromium (Co/Cr) ratio is thought to be associated with
corrosion of the trunnion and increased adverse local tissue reaction (ALTR) risk in patients …

Predictive factors for metal ion levels in metal-on-metal total hip arthroplasty

MF Kasparek, L Renner, M Faschingbauer… - Archives of Orthopaedic …, 2018 - Springer
Introduction Although metal-on-metal (MoM) total hip arthroplasty (THA) and hip
resurfacings (HR) have similar bearing surfaces and comparable wear rates, metal ion …

Adverse Tissue Reactions and Metal Ion Behavior After Small‐Head Metasul Hip Arthroplasty: A Long‐Term Follow‐Up Study

T Ishida, T Tateiwa, Y Takahashi… - Orthopaedic …, 2022 - Wiley Online Library
Objective To investigate the long‐term survivorship, incidence of adverse reactions to metal
debris (ARMD), and metal ion behavior in patients who underwent small‐head Metasul …

Periprosthetic acetabular radiolucency progression in mid-term follow-up of the articular surface replacement hip system

SJ Matuszak, VP Galea, JW Connelly… - Archives of Orthopaedic …, 2018 - Springer
Introduction Recent registry studies show that aseptic loosening secondary to osteolysis is
the second leading cause of hip implant failure in patients implanted with metal-on-metal …

[HTML][HTML] In vivo analysis of the effects of CoCrMo and Ti particles on inflammatory responses and osteolysis

J Li, Y Li, X Peng, B Li, H Qin, Y Chen - RSC advances, 2018 - pubs.rsc.org
Metal wear particles play a major role in periprosthetic osteolysis and aseptic loosening in
patients with total joint arthroplasty. The ability to induce osteolysis depends on the size …

[HTML][HTML] 磨损颗粒刺激下小鼠骨髓来源巨噬细胞调控白细胞介素-34 表达的实验研究

刘子歌, 张晨, 宋国瑞, 陈德胜 - 中国医科大学学报, 2021 - html.rhhz.net
目的探讨白细胞介素-34 (IL-34) 在体外是否可以促进破骨细胞形成以及在磨损颗粒刺激下小鼠
骨髓来源巨噬细胞(BMMs) 中IL-34 的体外表达量和相关机制. 方法提取小鼠BMMs 原代细胞 …

Metal-on-metal surface hip arthroplasties. Is annual monitoring of blood metal levels necessary?

D Hernández-Vaquero, M García-Pascual… - Revista Española de …, 2018 - Elsevier
Abstract Introduction Blood cobalt (Co) and chromium (Cr) ion levels have been used as
surveillance tools for adverse reaction to metal debris in metal-on-metal (MoM) hip …

Do cobalt and chromium blood metal ion levels normalize after revision of failed metal-on-metal total hip replacements?

A Jungwirth-Weinberger, C Hanreich… - Archives of Orthopaedic …, 2023 - Springer
Abstract Introduction Increased cobalt (Co) and chromium (Cr) serum levels are one reason
for revision surgery in metal on metal (MoM) total hip arthroplasty (THA) patients. Dual …

Inferior radiographic and functional outcomes with modular stem in metal-on-metal total hip arthroplasty

I Laaksonen, VP Galea, JW Connelly… - The Journal of …, 2018 - Elsevier
Background Data on the association between stem type and metal-on-metal (MoM) total hip
arthroplasty (THA) performance are limited. The aim of this study is to investigate the effect of …