Absent posteroinferior and anterosuperior atrial septal defect rims: factors affecting nonsurgical closure of large secundum defects using the Amplatzer occluder
JW Mathewson, D Bichell, A Rothman, FF Ing - Journal of the American …, 2004 - Elsevier
Using transesophageal echocardiography, we sought to determine the anatomic
characteristics of the secundum atrial septal defects (ASDs) that extend into the inferior sinus …
characteristics of the secundum atrial septal defects (ASDs) that extend into the inferior sinus …
Transcatheter atrial septal defect closure: modified balloon sizing technique to avoid overstretching the defect and oversizing the Amplatzer septal occluder
KM Carlson, H Justino, RE O'Brien… - Catheterization and …, 2005 - Wiley Online Library
The objective of this study was to evaluate a new technique of sizing atrial septal defects
(ASDs) for transcatheter device closure. ASD closure using the Amplatzer septal occluder …
(ASDs) for transcatheter device closure. ASD closure using the Amplatzer septal occluder …
Transcatheter closure of atrial septal defects improves right ventricular volume, mass, function, pulmonary pressure, and functional class: a magnetic resonance …
SP Schoen, T Kittner, S Bohl, MU Braun, G Simonis… - Heart, 2006 - heart.bmj.com
Objective: To characterise prospectively by magnetic resonance imaging (MRI) changes in
right ventricular (RV) volume, function, and mass after transcatheter closure of atrial septal …
right ventricular (RV) volume, function, and mass after transcatheter closure of atrial septal …
Role of Intracardiac Echocardiographic Guidance in Transcatheter Closure of Atrial Septal Defects and Patent Foramen Ovale Using the Amplatzer® Device
P Koenig, QIL CAO, M Heitschmidt… - Journal of …, 2003 - Wiley Online Library
Transesophageal echocardiography (TEE) has been successfully used for guiding
transcatheter device closure of secundum atrial septal defect (ASD) and patent foramen …
transcatheter device closure of secundum atrial septal defect (ASD) and patent foramen …
Transcatheter closure of very large (≥ 25 mm) atrial septal defects using the Amplatzer septal occluder
BRJ Kannan, E Francis, K Sivakumar… - Catheterization and …, 2003 - Wiley Online Library
Abstract Between June 1999 and September 2002, 45 patients (age, 34±13 years; mean
shunt ratio, 2.6±0.6) underwent transcatheter atrial septal defect (ASD) closure at our …
shunt ratio, 2.6±0.6) underwent transcatheter atrial septal defect (ASD) closure at our …
Transcatheter closure of atrial septal defect in a geriatric population
K Nakagawa, T Akagi, M Taniguchi… - Catheterization and …, 2012 - Wiley Online Library
Objectives: To evaluate the efficacy and safety of transcatheter closure of atrial septal
defects (ASD) in patients over 70 years of age. Background: Transcatheter closure of ASD is …
defects (ASD) in patients over 70 years of age. Background: Transcatheter closure of ASD is …
Device closure of secundum atrial septal defects in children< 15 kg: Complication rates and indications for referral
S Bartakian, TE Fagan, MS Schaffer, JR Darst - JACC: Cardiovascular …, 2012 - jacc.org
Objectives: This study sought to determine institutional complication rates in a previously
underreported patient population and discuss referral indications. Background: There has …
underreported patient population and discuss referral indications. Background: There has …
Results of transvenous occlusion of secundum atrial septal defects with the fourth generation buttoned device: comparison with first, second and third generation …
PS Rao, F Berger, C Rey, J Haddad, B Meier… - Journal of the American …, 2000 - jacc.org
OBJECTIVES The purpose of this study was to assess safety and effectiveness of the fourth
generation buttoned device in closing atrial septal defects (ASDs) and to test the hypothesis …
generation buttoned device in closing atrial septal defects (ASDs) and to test the hypothesis …
Treatment of atrial septal defects in symptomatic children aged less than 2 years of age using the Amplatzer septal occluder
AimsTo assess results of closure of atrial septal defects within the oval fossa by devices
delivered by catheterisation in symptomatic infants and children under 2 years of age …
delivered by catheterisation in symptomatic infants and children under 2 years of age …
Choice of device size and results of transcatheter closure of atrial septal defect using the amplatzer septal occluder
ZD DU, QIL CAO, J Rhodes… - Journal of …, 2002 - Wiley Online Library
The impact of device size choice on closure results was analyzed in 138 (101 females, 37
males; age 0.5–84.0 years) consecutive patients who underwent transcatheter closure of the …
males; age 0.5–84.0 years) consecutive patients who underwent transcatheter closure of the …