[HTML][HTML] An overview of cochlear implant electrode array designs

A Dhanasingh, C Jolly - Hearing research, 2017 - Elsevier
Cochlear implant electrode arrays are designed with specific characteristics that allow for
the preservation of intra-cochlear structures during the insertion process, as well as during …

Conservation of hearing and protection of hair cells in cochlear implant patients' with residual hearing

E Bas, CT Dinh, C Garnham, M Polak… - … Record: Advances in …, 2012 - Wiley Online Library
This review covers the molecular mechanisms involved in hair cell and hearing losses which
can result from trauma generated during the process of cochlear implantation and the …

Damage to inner ear structure during cochlear implantation: Correlation between insertion force and radio-histological findings in temporal bone specimens

D De Seta, R Torres, FY Russo, E Ferrary… - Hearing research, 2017 - Elsevier
Cochlear implant insertion should be as least traumatic as possible in order to reduce
trauma to the cochlear sensory structures. The force applied to the cochlea during array …

[HTML][HTML] A new paradigm of hearing loss and preservation with cochlear implants: Learnings from fundamental studies and clinical research

JR Kirk, D Smyth, WF Dueck - Hearing research, 2023 - Elsevier
In 2010 Cochlear initiated a coordinated preclinical research program to identify the factors
and underlying mechanisms of acoustic hearing loss following cochlear implantation and …

[HTML][HTML] Impact of scala tympani geometry on insertion forces during implantation

F Hrncirik, IV Roberts, C Swords, PJ Christopher… - Biosensors, 2022 - mdpi.com
(1) Background: During a cochlear implant insertion, the mechanical trauma can cause
residual hearing loss in up to half of implantations. The forces on the cochlea during the …

Investigation of ultra-low insertion speeds in an inelastic artificial cochlear model using custom-made cochlear implant electrodes

S Hügl, K Rülander, T Lenarz, O Majdani… - European Archives of Oto …, 2018 - Springer
Purpose Latest research on cochlear implantations focuses on hearing preservation during
insertion of the implant's electrode array by reducing insertion trauma. One parameter which …

Friction force measurement during cochlear implant insertion: application to a force-controlled insertion tool design

M Miroir, Y Nguyen, G Kazmitcheff, E Ferrary… - Otology & …, 2012 - journals.lww.com
Background Today, the surgical challenge in cochlear implantation is the preservation of the
anatomic structures and the residual hearing. In routine practice, the electrode array is …

Modeling, design, and evaluation of a parallel robot for cochlear implant surgery

J Pile, N Simaan - IEEE/ASME Transactions on Mechatronics, 2014 - ieeexplore.ieee.org
Cochlear implant surgery is a procedure that requires delicate insertion of an electrode array
into the inner ear. This paper reports the clinical motivation, design considerations, analysis …

Anatomically and mechanically accurate scala tympani model for electrode insertion studies

A Starovoyt, E Shaheen, T Putzeys, G Kerckhofs… - Hearing Research, 2023 - Elsevier
The risk of insertion trauma in cochlear implantation is determined by the interplay between
individual cochlear anatomy and electrode insertion mechanics. Whereas patient anatomy …

[HTML][HTML] Fabrication of human anatomy-based scala tympani models with a hydrophilic coating for cochlear implant insertion experiments

P Aebischer, M Caversaccio, W Wimmer - Hearing research, 2021 - Elsevier
Electrode array insertion into the inner ear is a critical step in cochlear implantation, and
artificial scala tympani models can be a valuable tool for studying the dynamics of this …