[HTML][HTML] Lessons learnt from the recent EURADOS intercomparisons in computational dosimetry
H Rabus, M Zankl, JM Gómez-Ros, C Villagrasa… - Radiation …, 2022 - Elsevier
Abstract Organized by Working Group 6 “Computational Dosimetry” of the European
Radiation Dosimetry Group (EURADOS), a group of intercomparison exercises was …
Radiation Dosimetry Group (EURADOS), a group of intercomparison exercises was …
Current status of TRIPOLI-4® monte carlo radiation transport code on adult and pediatric computational phantoms for radiation dosimetry study
TRIPOLI-4® is a general-purpose Monte Carlo radiation transport code developed by the
Service d'Études des Réacteurs et de Mathématiques Appliquées at CEA-Saclay. It uses …
Service d'Études des Réacteurs et de Mathématiques Appliquées at CEA-Saclay. It uses …
Monte Carlo simulations of the whole-body counter at Spiez Laboratory Switzerland: Impact of phantom size and biokinetic model
L Desorgher, N Mosimann, R Althaus, C Wirz… - Radiation …, 2022 - Elsevier
Whole-body counters (WBC) are used to detect potential intake of radioisotopes in the
human body. To achieve a precise measurement of an incorporated activity, a WBC needs …
human body. To achieve a precise measurement of an incorporated activity, a WBC needs …
Evaluating operator's organ dose and effective dose according to the lead equivalent of radiation protection devices in performing angiography and interventional …
DH Han, MS Han, SJ Lee, BS Shin, JO Kim… - Journal of the Korean …, 2023 - Springer
The purpose of the study was to evaluate the radiation dose in High-Definition Reference
Korean-Man phantom according to the lead equivalent in the protection devices using …
Korean-Man phantom according to the lead equivalent in the protection devices using …
Direct Monitoring Method to Detect Internal Radioactive Contamination
Direct monitoring technique for evaluation of internal contamination is a century old mature
method used for assessment of internal dose. It is used for estimation of organ/whole body …
method used for assessment of internal dose. It is used for estimation of organ/whole body …
Monte Carlo in Internal Dosimetry
In internal dosimetry, the Monte Carlo technique is used for radiation transport to compute
values of efficiency of monitoring systems and energy deposition in various organs followed …
values of efficiency of monitoring systems and energy deposition in various organs followed …
EURADOS working group 6, computational dosimetry, a history of promoting good practice via intercomparisons and training
This paper is the editorial of a special issue of Radiation Measurements on EURADOS
intercomparisons in computational dosimetry. The articles in this special issue cover …
intercomparisons in computational dosimetry. The articles in this special issue cover …