Hearing preservation in cochlear implant surgery: a meta-analysis

C Snels, J IntHout, E Mylanus, W Huinck… - Otology & …, 2019 - journals.lww.com
Hearing Preservation in Cochlear Implant Surgery: A Meta-Ana... : Otology & Neurotology
Hearing Preservation in Cochlear Implant Surgery: A Meta-Analysis : Otology & Neurotology …

Hearing preservation cochlear implant surgery

IA Bruce, I Todt - Advances in Hearing Rehabilitation, 2018 - karger.com
Cochlear implantation (CI), with attempted preservation of residual natural low-frequency
hearing, is an increasingly accepted application of this technology, with potential benefits to …

Evaluation of insertion forces and cochlea trauma following robotics-assisted cochlear implant electrode array insertion

CR Kaufmann, AM Henslee, A Claussen… - Otology & …, 2020 - journals.lww.com
Background: Variability in CI outcomes exists across patients, implant centers, surgeons,
and electrode types. While surgical techniques that reduce electrode insertion trauma are …

The use of a robot to insert an electrode array of cochlear implants in the cochlea: a feasibility study and preliminary results

S Barriat, N Peigneux, U Duran, S Camby… - Audiology and …, 2021 - karger.com
Abstract Introduction: Cochlear implants (CIs) are commonly used for the rehabilitation of
profound bilateral hearing loss. However, patients with substantial residual acoustic hearing …

The effect of ultra-slow velocities on insertion forces: a study using a highly flexible straight electrode Array

MG Zuniga, S Hügl, BG Engst, T Lenarz… - Otology & …, 2021 - journals.lww.com
Objective: The present study sought to 1) characterize insertion forces resulting from a
flexible straight electrode array (EA) inserted at slow and ultra-slow insertion velocities, and …

A steadier hand: the first human clinical trial of a single-use robotic-assisted surgical device for cochlear implant electrode array insertion

JA Gantz, BJ Gantz, CR Kaufmann… - Otology & …, 2023 - journals.lww.com
A Steadier Hand: The First Human Clinical Trial of a Single-... : Otology & Neurotology A
Steadier Hand: The First Human Clinical Trial of a Single-Use Robotic-Assisted Surgical Device …

Intracochlear pressure transients during cochlear implant electrode insertion

NT Greene, JK Mattingly, RMB Hartl… - Otology & …, 2016 - journals.lww.com
Background: Many patients receiving a CI have some remaining functional hearing at low
frequencies; thus, devices and surgical techniques have been developed to use this …

Comparative analysis of robotics-assisted and manual insertions of cochlear implant electrode arrays

AD Claussen, SB Shibata, CR Kaufmann… - Otology & …, 2022 - journals.lww.com
Background Whether intracochlear trauma and translocations are two factors that may
contribute to significant variability in CI outcomes remains to be seen. To address this issue …

Polymeric fiber sensors for insertion forces and trajectory determination of cochlear implants in hearing preservation

DS Gunawardena, J Cui, X Cheng, AN Vadivelu… - Biosensors and …, 2023 - Elsevier
The level of hearing restoration in patients with severe to profound sensorineural hearing
loss by means of cochlear implants (CIs) has drastically risen since the introduction of these …

Investigation of ultra-low insertion speeds in an inelastic artificial cochlear model using custom-made cochlear implant electrodes

S Hügl, K Rülander, T Lenarz, O Majdani… - European Archives of Oto …, 2018 - Springer
Purpose Latest research on cochlear implantations focuses on hearing preservation during
insertion of the implant's electrode array by reducing insertion trauma. One parameter which …