Hearing preservation in cochlear implant surgery: a meta-analysis
Hearing Preservation in Cochlear Implant Surgery: A Meta-Ana... : Otology & Neurotology
Hearing Preservation in Cochlear Implant Surgery: A Meta-Analysis : Otology & Neurotology …
Hearing Preservation in Cochlear Implant Surgery: A Meta-Analysis : Otology & Neurotology …
Hearing preservation cochlear implant surgery
Cochlear implantation (CI), with attempted preservation of residual natural low-frequency
hearing, is an increasingly accepted application of this technology, with potential benefits to …
hearing, is an increasingly accepted application of this technology, with potential benefits to …
Evaluation of insertion forces and cochlea trauma following robotics-assisted cochlear implant electrode array insertion
CR Kaufmann, AM Henslee, A Claussen… - Otology & …, 2020 - journals.lww.com
Background: Variability in CI outcomes exists across patients, implant centers, surgeons,
and electrode types. While surgical techniques that reduce electrode insertion trauma are …
and electrode types. While surgical techniques that reduce electrode insertion trauma are …
The use of a robot to insert an electrode array of cochlear implants in the cochlea: a feasibility study and preliminary results
S Barriat, N Peigneux, U Duran, S Camby… - Audiology and …, 2021 - karger.com
Abstract Introduction: Cochlear implants (CIs) are commonly used for the rehabilitation of
profound bilateral hearing loss. However, patients with substantial residual acoustic hearing …
profound bilateral hearing loss. However, patients with substantial residual acoustic hearing …
The effect of ultra-slow velocities on insertion forces: a study using a highly flexible straight electrode Array
MG Zuniga, S Hügl, BG Engst, T Lenarz… - Otology & …, 2021 - journals.lww.com
Objective: The present study sought to 1) characterize insertion forces resulting from a
flexible straight electrode array (EA) inserted at slow and ultra-slow insertion velocities, and …
flexible straight electrode array (EA) inserted at slow and ultra-slow insertion velocities, and …
A steadier hand: the first human clinical trial of a single-use robotic-assisted surgical device for cochlear implant electrode array insertion
JA Gantz, BJ Gantz, CR Kaufmann… - Otology & …, 2023 - journals.lww.com
A Steadier Hand: The First Human Clinical Trial of a Single-... : Otology & Neurotology A
Steadier Hand: The First Human Clinical Trial of a Single-Use Robotic-Assisted Surgical Device …
Steadier Hand: The First Human Clinical Trial of a Single-Use Robotic-Assisted Surgical Device …
Intracochlear pressure transients during cochlear implant electrode insertion
NT Greene, JK Mattingly, RMB Hartl… - Otology & …, 2016 - journals.lww.com
Background: Many patients receiving a CI have some remaining functional hearing at low
frequencies; thus, devices and surgical techniques have been developed to use this …
frequencies; thus, devices and surgical techniques have been developed to use this …
Comparative analysis of robotics-assisted and manual insertions of cochlear implant electrode arrays
AD Claussen, SB Shibata, CR Kaufmann… - Otology & …, 2022 - journals.lww.com
Background Whether intracochlear trauma and translocations are two factors that may
contribute to significant variability in CI outcomes remains to be seen. To address this issue …
contribute to significant variability in CI outcomes remains to be seen. To address this issue …
Polymeric fiber sensors for insertion forces and trajectory determination of cochlear implants in hearing preservation
The level of hearing restoration in patients with severe to profound sensorineural hearing
loss by means of cochlear implants (CIs) has drastically risen since the introduction of these …
loss by means of cochlear implants (CIs) has drastically risen since the introduction of these …
Investigation of ultra-low insertion speeds in an inelastic artificial cochlear model using custom-made cochlear implant electrodes
Purpose Latest research on cochlear implantations focuses on hearing preservation during
insertion of the implant's electrode array by reducing insertion trauma. One parameter which …
insertion of the implant's electrode array by reducing insertion trauma. One parameter which …