A meta-analysis comparing ProCore and standard fine-needle aspiration needles for endoscopic ultrasound-guided tissue acquisition
JY Bang, R Hawes, S Varadarajulu - Endoscopy, 2016 - thieme-connect.com
Background and study aims: To overcome the limitations associated with cytology, a
uniquely designed needle (ProCore) was introduced in an effort to obtain a core of tissue …
uniquely designed needle (ProCore) was introduced in an effort to obtain a core of tissue …
A meta-analysis of endoscopic ultrasound–fine-needle aspiration compared to endoscopic ultrasound–fine-needle biopsy: diagnostic yield and the value of onsite …
Background The diagnostic yield of endoscopic ultrasound (EUS) guided fine-needle
aspiration (FNA) is variable, and partly dependent upon rapid onsite evaluation (ROSE) by a …
aspiration (FNA) is variable, and partly dependent upon rapid onsite evaluation (ROSE) by a …
Technical aspects of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Technical …
M Polkowski, C Jenssen, P Kaye, S Carrara… - …, 2017 - thieme-connect.com
For routine EUS-guided sampling of solid masses and lymph nodes (LNs) ESGE
recommends 25G or 22G needles (high quality evidence, strong recommendation); fine …
recommends 25G or 22G needles (high quality evidence, strong recommendation); fine …
Successful creation of pancreatic cancer organoids by means of EUS-guided fine-needle biopsy sampling for personalized cancer treatment
H Tiriac, JC Bucobo, D Tzimas, S Grewel… - Gastrointestinal …, 2018 - Elsevier
Background and Aims Pancreatic cancer organoids are tumor models of individualized
human pancreatic ductal adenocarcinoma (PDA), created from surgical specimens and …
human pancreatic ductal adenocarcinoma (PDA), created from surgical specimens and …
Comparison of fine-needle aspiration and fine-needle biopsy devices for endoscopic ultrasound-guided sampling of solid lesions: a systemic review and meta …
PA van Riet, NS Erler, MJ Bruno, DL Cahen - Endoscopy, 2021 - thieme-connect.com
Background Endoscopic ultrasound (EUS)-guided tissue acquisition is extensively used, but
the optimal sampling device is still a matter of debate. We performed meta-analyses on …
the optimal sampling device is still a matter of debate. We performed meta-analyses on …
Analysis of fine-needle biopsy vs fine-needle aspiration in diagnosis of pancreatic and abdominal masses: a prospective, multicenter, randomized controlled trial
B Cheng, Y Zhang, Q Chen, B Sun, Z Deng… - Clinical …, 2018 - Elsevier
Background & Aims Endoscopic ultrasound (EUS)-guided fine needles with side
fenestrations are used to collect aspirates for cytology analysis and biopsy samples for …
fenestrations are used to collect aspirates for cytology analysis and biopsy samples for …
EFSUMB guidelines on interventional ultrasound (INVUS), Part IV–EUS-guided interventions: General aspects and EUS-guided sampling (long version)
C Jenssen, M Hocke, P Fusaroli… - Ultraschall in der …, 2016 - thieme-connect.com
The fourth part of the European Federation of Societies for Ultrasound in Medicine and
Biology (EFSUMB) Guidelines on Interventional Ultrasound describes general aspects of …
Biology (EFSUMB) Guidelines on Interventional Ultrasound describes general aspects of …
A multicenter randomized trial comparing a 25-gauge EUS fine-needle aspiration device with a 20-gauge EUS fine-needle biopsy device
Background and Aims Several studies have compared EUS-guided FNA with fine-needle
biopsy (FNB), but none have proven superiority. We performed a multicenter randomized …
biopsy (FNB), but none have proven superiority. We performed a multicenter randomized …
Comparison of 22G reverse-beveled versus standard needle for endoscopic ultrasound-guided sampling of solid pancreatic lesions
A Alatawi, F Beuvon, S Grabar… - United European …, 2015 - journals.sagepub.com
Objectives Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) using standard
needles has a high diagnostic value in the evaluation of solid pancreatic masses …
needles has a high diagnostic value in the evaluation of solid pancreatic masses …
Comparison between 22G aspiration and 22G biopsy needles for EUS-guided sampling of pancreatic lesions: A meta-analysis
A Facciorusso, HS Bajwa, K Menon… - Endoscopic …, 2020 - journals.lww.com
Robust data in favor of clear superiority of 22G fine-needle biopsy (FNB) over 22G FNA for
an echoendoscopic-guided sampling of pancreatic masses are lacking. The objective of this …
an echoendoscopic-guided sampling of pancreatic masses are lacking. The objective of this …