Doppler velocity criteria based on receiver operating characteristic analysis for the detection of threshold carotid stenoses

CS Hwang, WY Shau, CH Tegeler - Journal of Neuroimaging, 2002 - Wiley Online Library
Background and Purpose. Duplex scanning is an accepted method for noninvasive
evaluation of carotid stenosis. However, the ultrasound criteria used for the detection of …

Usefulness of acceleration time for internal carotid artery origin stenosis

H Tamura, Y Akaiwa, K Onda - Annals of Vascular Diseases, 2013 - jstage.jst.go.jp
Calcification of the internal carotid artery (ICA) hinders accurate evaluation of the stenosis by
conventional ultrasonography due to acoustic shadow. We examined the relationship …

Carotid hemodynamic parameters are useful for discriminating between atherothrombotic infarction and lacunar infarction

Y Nishiyama, T Katsumata, T Otori… - Journal of Stroke and …, 2010 - Elsevier
Using ultrasound, we investigated whether carotid parameters differed among subtypes of
ischemic stroke and evaluated the usefulness of these parameters in discriminating among …

Flow observations in elastic stenosis biomodel with comparison to rigid-like model

Y Shimizu, A Javadzadegan… - … and Health care, 2013 - content.iospress.com
Background: Plaques in blood vessels exhibit a wide range of stiffness depending on
disease conditions: stiffness is an important factor in plaque behavior. The geometrical …

Rapid evaluation of large vessel occlusion for mechanical thrombectomy using carotid duplex ultrasound

R Itabashi, Y Shigehatake, T Saito, K Endo… - Internal …, 2023 - jstage.jst.go.jp
Objectives This study clarified the usefulness of carotid duplex ultrasound (CDU) in
evaluating large vessel occlusion (LVO) in patients with acute stroke planned to be treated …

Accuracy of the Society of Radiologists in Ultrasound (SRU) Carotid Doppler Velocity Criteria for Grading North American Symptomatic Carotid Endarterectomy Trial …

JF Polak, AV Alexandrov - Journal of Ultrasound in Medicine, 2023 - Wiley Online Library
Purpose The Society of Radiologists in Ultrasound (SRU) consensus panel proposed six
Doppler velocity cut points for classifying internal carotid artery (ICA) stenosis of 50% and …

Diagnostic performance of duplex ultrasound in patients suspected of carotid artery disease: the ipsilateral versus contralateral artery

MH Heijenbrok-Kal, PJ Nederkoorn, E Buskens… - Stroke, 2005 - Am Heart Assoc
Background and Purpose—To evaluate duplex ultrasonographic thresholds for the
determination of 70% to 99% stenosis of the ipsilateral and contralateral internal carotid …

Associations of local release of inflammatory biomarkers during carotid artery stenting with plaque echogenicity and calcification

Y Abe, M Sakaguchi, S Furukado, S Okazaki… - Cerebrovascular …, 2010 - karger.com
Background and Purpose: The purpose of this study is to evaluate whether release of
inflammatory markers locally from an atherosclerotic plaque after carotid artery stenting …

Usefulness of “AcT ratio” in diagnosis of internal carotid artery stenosis: a multicenter, retrospective, observational study

D Tsukui, H Takekawa, K Saito, R Okabe… - Journal of Medical …, 2024 - Springer
Purpose The ratio of the internal carotid artery (ICA) to the common carotid artery (CCA),
especially the “AcT ratio,” which is a modified measurement method of acceleration time, is …

Influence of plaque stiffness on deformation and blood flow patterns in models of stenosis

Y Shimizu, M Ohta - Biorheology, 2015 - content.iospress.com
BACKGROUND: Blood flow in stenotic vessels strongly influences the progression of
vascular diseases. Plaques in stenotic blood vessels vary in stiffness, which influences …