Conservative versus liberal oxygenation targets for mechanically ventilated patients. A pilot multicenter randomized controlled trial

R Panwar, M Hardie, R Bellomo, L Barrot… - American journal of …, 2016 - atsjournals.org
Rationale: There are no randomized controlled trials comparing different oxygenation
targets for intensive care unit (ICU) patients. Objectives: To determine whether a …

[HTML][HTML] Credibility evidence for computational patient models used in the development of physiological closed-loop controlled devices for critical care medicine

B Parvinian, P Pathmanathan, C Daluwatte… - Frontiers in …, 2019 - frontiersin.org
Physiological closed-loop controlled medical devices automatically adjust therapy delivered
to a patient to adjust a measured physiological variable. In critical care scenarios, these …

Physiological closed-loop control in intelligent oxygen therapy: A review

D Sanchez-Morillo, O Olaby… - Computer methods and …, 2017 - Elsevier
Abstract Background and Objective Oxygen therapy has become a standard care for the
treatment of patients with chronic obstructive pulmonary disease and other hypoxemic …

A sub-mW fully-integrated pulse oximeter front-end

KN Glaros, EM Drakakis - IEEE transactions on biomedical …, 2012 - ieeexplore.ieee.org
This paper presents the implementation of the first fully integrated pulse oximeter front-end
with a power consumption lower than 1 mW. This is enabled by system-and block-level …

Adaptive pulse width control and sampling for low power pulse oximetry

SV Gubbi, B Amrutur - IEEE transactions on biomedical circuits …, 2014 - ieeexplore.ieee.org
Remote sensing of physiological parameters could be a cost effective approach to improving
health care, and low-power sensors are essential for remote sensing because these sensors …

LED power reduction trade-offs for ambulatory pulse oximetry

EA Pelaez, ER Villegas - … of the IEEE Engineering in Medicine …, 2007 - ieeexplore.ieee.org
The development of ambulatory arterial pulse oximetry is key to longer term monitoring and
treatment of cardiovascular and respiratory conditions. The investigation presented in this …

Conservative versus conventional oxygen therapy in type I acute respiratory failure patients in respiratory intensive care unit, Zagazig University

RM Nafae, W Shouman… - … Archives for Chest …, 2024 - monaldi-archives.org
The present study aimed to assess the effect of conservative (permissive hypoxaemia)
versus conventional (normoxaemia) protocol for oxygen supplementation on outcome of …

Treatment of COPD: from pharmacological to instrumental therapies

M Alifano, A Cuvelier, A Delage… - European …, 2010 - Eur Respiratory Soc
Treatment guidelines are mainly based on randomised clinical trials that include a small and
highly selected fraction of the COPD population [2]. Therefore, it is questionable as to …

[PDF][PDF] Low-power pulse oximetry and transimpedance amplifiers

KN Glaros - 2011 - Citeseer
This work focuses on the design of low-power fully-integrated pulse oximeter front-ends and
transimpedance amplifiers. Mathematical modelling and numerical simulations are …

Assessment of validity and predictability of the FiO2–SpO2 transfer-function in preterm infants

OS Fathabadi, TJ Gale, K Lim, BP Salmon… - Physiological …, 2014 - iopscience.iop.org
In this paper an investigation of the gain, delay, and time-constant parameters of the transfer
function describing the relation between fraction of inspired oxygen (FiO 2) and oxygen …