Magnetic field induced dose effects in radiation therapy using MR‐linacs
MR‐guided radiotherapy (MRgRT) is one of the most significant advances in radiotherapy in
recent years. The hybrid systems were designed to visualize patient anatomical and …
recent years. The hybrid systems were designed to visualize patient anatomical and …
MRgRT quality assurance for a low-field MR-linac
JP Kim - Seminars in radiation oncology, 2024 - Elsevier
The introduction of MR-guided treatment machines into the radiation oncology clinic has
provided unique challenges for the radiotherapy QA program. These MR-linac systems …
provided unique challenges for the radiotherapy QA program. These MR-linac systems …
A multi-institutional comparison of dosimetric data for a 0.35 T MR-linac
AU Khan, R Lotey, LA DeWerd… - Physics in Medicine & …, 2022 - iopscience.iop.org
Objective. A comparison of percent depth dose (PDD) curves, lateral beam profiles, output
factors (OFs), multileaf collimator (MLC) leakage, and couch transmission factors was …
factors (OFs), multileaf collimator (MLC) leakage, and couch transmission factors was …
Development and clinical application of a GPU‐based Monte Carlo dose verification module and software for 1.5 T MR‐LINAC
B Cheng, Y Xu, S Li, Q Ren, X Pei, K Men… - Medical …, 2023 - Wiley Online Library
Background Adaptive radiotherapy (ART) has made significant advances owing to magnetic
resonance linear accelerator (MR‐LINAC), which provides superior soft‐tissue contrast, fast …
resonance linear accelerator (MR‐LINAC), which provides superior soft‐tissue contrast, fast …
An independent Monte Carlo–based IMRT QA tool for a 0.35 T MRI‐guided linear accelerator
AU Khan, EA Simiele, R Lotey… - Journal of Applied …, 2023 - Wiley Online Library
Purpose To develop an independent log file–based intensity‐modulated radiation therapy
(IMRT) quality assurance (QA) tool for the 0.35 T magnetic resonance‐linac (MR‐linac) and …
(IMRT) quality assurance (QA) tool for the 0.35 T magnetic resonance‐linac (MR‐linac) and …
Dosimetric effects of air cavities for MRI-guided online adaptive radiation therapy (MRgART) of prostate bed after radical prostatectomy
Purpose: To evaluate dosimetric impact of air cavities and their corresponding electron
density correction for 0.35 tesla (T) Magnetic Resonance-guided Online Adaptive Radiation …
density correction for 0.35 tesla (T) Magnetic Resonance-guided Online Adaptive Radiation …
Commissioning a secondary dose calculation software for a 0.35 T MR‐linac
AT Price, NC Knutson, T Kim… - Journal of applied clinical …, 2022 - Wiley Online Library
Secondary external dose calculations for a 0.35 T magnetic resonance image‐guided
radiation therapy (MRgRT) are needed within the radiation oncology community to follow …
radiation therapy (MRgRT) are needed within the radiation oncology community to follow …
Dosimetric evaluation of off-axis fields and angular transmission for the 1.5 T MR-linac
M van den Dobbelsteen, SL Hackett… - Physics in Medicine …, 2022 - iopscience.iop.org
Objective. GPU-oriented Monte Carlo dose (GPUMCD) is a fast dose calculation algorithm
used for treatment planning on the Unity MR-linac. Treatments for the MR-linac must be …
used for treatment planning on the Unity MR-linac. Treatments for the MR-linac must be …
MR compatible detectors assessment for a 0.35 T MR-linac commissioning
M Chea, M Croisé, C Huet, C Bassinet… - Radiation …, 2024 - Springer
Purpose To assess a large panel of MR compatible detectors on the full range of
measurements required for a 0.35 T MR-linac commissioning by using a specific statistical …
measurements required for a 0.35 T MR-linac commissioning by using a specific statistical …
[HTML][HTML] Dosimetric impact of CT metal artifact reduction for spinal implants in stereotactic body radiotherapy planning
B Li, J Huang, J Ruan, Q Peng, S Huang… - Quantitative Imaging in …, 2023 - ncbi.nlm.nih.gov
Background Metal artifacts due to spinal implants may affect the accuracy of dose
calculation for radiotherapy. However, the dosimetric impact of metal artifact reduction …
calculation for radiotherapy. However, the dosimetric impact of metal artifact reduction …